Ricoh D131 Service Manual page 557

Table of Contents

Advertisement

SC900: Miscellaneous
Recovery Procedure 4
If "Recovery Procedures 1 to 3" fail to correct the problem, replace the HDD.
SC910
SC911
SC912
SC913
B
SC914
SC915
A
External Controller Error 6
While EAC (External Application Converter), the conversion module,
was operating normally, the receipt of a power line interrupt signal
from the FLUTE serial driver was detected, of BREAK signal from
SC919
B
the other station was detected.
D131/D132/D133
External Controller Error 1
External Controller Error 2
External Controller Error 3
External Controller Error 4
External Controller Error 5
The external controller alerted the machine about an error.
For more, refer to the instructions for the external controller.
External Controller Error 6
Egret board error
The external controller alerted the machine about an error.
Replace the Egret controller board.
Power outage at the EFI controller.
EFI controller was rebooted.
Connection to EFI controller loose.
Cycle the machine off/on
2-90
GW
SM Appendix

Hide quick links: