Fusing Unit

Reinstallation

To prevent damage to a thermostat, never touch its detection surface.
Place the end of the thermostat harness that has the round lead [A] in between the two ribs
,
in the bracket.
Tighten the screw for the round lead [A] as tight as possible without damaging the screw or
screw hole.
If the harness is not positioned between the between the bracket ribs
under "Incorrect" below), this could cause an error (SC542 or SC545).

4.9.3 WEB CLEANING ROLLER

Web Unit Disassembly

1.
Open the front door and pull out the fusing unit on its support rails.
2.
Web unit [A] (
x 2,
The web unit can be removed without removing the fusing unit from the machine.
D131/D132/D133
x 2)
4-72
,
(as shown