Ricoh D131 Service Manual page 703

Table of Contents

Advertisement

SP5000 Mode: SP5821 to SP5990
3.7 SP5000 MODE: SP5821 TO SP5990
5821
Remote Service Address
2 RCG IP Address
Sets the IP address of the RCG (Remote Communication Gate) destination
for call processing at the remote service center.
3 RCG Port Number
Sets the RCG port number of the destination for processing calls to the
@Remote service center.
[0 to 65 535/443/1]
4 RCG URL Path
Sets the URL path of the destination for processing calls to the @Remote
service center.
17 Numeric characters allowed (0 to 17)
NVRAM Data Upload
Uploads the UP and SP mode data (except for counters and the serial
5824
number) from NVRAM on the control board to an SD card.
Note: While using this SP mode, always keep the front cover open. This
prevents a software module accessing the NVRAM during the upload.
NVRAM Data Download
Downloads data from an SD card to the NVRAM in the machine. After
5825
downloading is completed, remove the SD card and turn the machine power
off and on.
D131/D132/D133
3-128
CTL
SM Appendix

Hide quick links: