SP1000 Feed
9 Capapcitor Heater Temperature Japan only
Capacitator for Check Start Fusing Temperature
[170 to 205/200/1 deg C]
10 Capacitor Heater Actual time Japan only
Capacitator for Check Start Fusing Lamp ON Time
[0 to 120/0/1 sec.]
11 Center Lamp Temp (Label)
D131/D132: [150 to 205/200/1 degree C]
D133: [150 to 205/195/1 degree C]
12 Center Lamp Actual Time
[0 to 120/0/1 degree C]
13 End Lamp Temp (Label)
D131/D132: [150 to 205/200/1 degree C]
D133: [150 to 205/195/1 degree C]
14 Center Lamp Actual Time (Label)
[0 to 120/0/1 degree C]
15 Center Lamp Temp (Tab Sheet)
D131/D132: [150 to 205/200/1 degree C]
D133: [150 to 205/195/1 degree C]
16 Center Lamp Actual Time (Tab Sheet)
[0 to 120/0/1 degree C]
17 End Lamp Temp (Tab Sheet)
D131/D132: [150 to 205/200/1 degree C]
D133: [150 to 205/195/1 degree C]
18 End Lamp Actual Time (Tab Sheet)
[0 to 120/0/1 degree C]