the battery voltage drops as a result of discharge and will turn off
when batteries are fully charged.
Battery Only Operating Mode
The machine will operate in the battery only mode when:
1. Ground Control EMS is pulled out, and:
2. The switch on the platform control console is in the Off or
Disable position.
The batteries can be used until they are fully discharged.
Manual (Charge) Operating Mode
The generator will operate in manual mode when:
1. Ground Control EMS is pulled out, and:
2. The switch on the platform control console is in the On or
Enable position and:
3. The Manual Charge push button is activated.
Activation of the Manual Charge button will start the engine and
begin the charging cycle even if the batteries are charged above
the level of automatic start.
3121217
4.9
FUNCTION SPEED CONTROL
This control affects the speed of all boom functions and Platform
Rotate. When in the CCW maximum position, Drive is placed in
creep speed.
4.10 MACHINE SAFETY SYSTEM OVERRIDE (MSSO)(CE
ONLY)
The Machine Safety System Override (MSSO) is
used to override function controls for Emergency
Platform Retrieval only. Refer to Section 5.6,
Machine Safety System Override (MSSO)(CE
Only)for operating procedures.
– JLG Lift –
SECTION 4 - MACHINE OPERATION
4-9