SECTION 3 - MACHINE CONTROLS AND INDICATORS
15. Indicator Gauge
Registers the amount of time the machine has been in use,
with functions operating. In the event of a fault, the hourme-
ter also displays the three digit fault code. Refer to the Ser-
vice Manual for a listing of fault codes. Additionally, there is a
small, red indicator light that will blink when there is a fault
on the machine to draw operator attention to the display.
16. Charger Status
The Charger Status LEDs give a visual indicator of the status
of the battery charger. The red LED indicates Charging
Abnormal. The yellow LED indicates charging in progress.
The green LED indicates charging is complete.
17. Machine Safety System Override (MSSO) (CE
Only)
Provides emergency override of function
controls that are locked out in the event of
Load Sense System activation.
3-8

Platform Control Station

(See Figure 3-4., Platform Control Station)
1. Power/Emergency Stop
A two-position red mushroom shaped switch furnishes
power to PLATFORM Controls when pulled out (on). When
pushed in (off ), power is shut off to the platform functions.
Within about 2 seconds of pulling the switch out, the
machine will perform a diagnostic check of the various elec-
trical circuits, and if everything is OK, the platform alarm will
beep once. During this time the lights on the indicator panel
will also blink once as a bulb check.
TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY CONTROL LEVERS OR
TOGGLE SWITCHES CONTROLLING PLATFORM MOVEMENT DO NOT RETURN TO THE
OFF OR NEUTRAL POSITION WHEN RELEASED.