SECTION 4 - MACHINE OPERATION
4.8

GENERATOR (OPTIONAL)

Automatic Operating Mode

The generator will operate in automatic mode when:
1.
Ground Control Emergency Stop is pulled out (On), and:
2.
The Generator Enable switch on the platform control con-
sole is in the On or Enable position.
When the above conditions apply, the generator's controller will
monitor status of the batteries, will turn on automatically when
the battery voltage drops as a result of discharge and will turn off
when batteries are fully charged.

Battery Only Operating Mode

The machine will operate in the battery only mode when:
1.
Ground Control Emergency Stop is pulled out, and:
2.
The switch on the platform control console is in the Off or
Disable position.
The batteries can be used until they are fully discharged.
4-10

Manual (Charge) Operating Mode

The generator will operate in manual mode when:
1.
Ground Control Emergency Stop is pulled out, and:
2.
The switch on the platform control console is in the On or
Enable position and:
3.
The Manual Charge push button is activated.
Activation of the Manual Charge button will start the engine and
begin the charging cycle even if the batteries are charged above
the level of automatic start.
4.9

FUNCTION SPEED CONTROL

This control affects the speed of all boom functions and Platform
Rotate. When in the counter cloackwise maximum position, Drive
is placed in Creep speed.
31215027