LOWERING THE BOOM
1. Push the control lever on the valve up.
2. Install the handle into the hand pump and pump the handle
until the desired platform position is reached.
3. Push the control lever down when complete. Remove the
handle from the hand pump.
3121217
SWING RIGHT
1. Install the spool plug in the location shown.
2. Install the handle into the hand pump and pump the handle
until the desired platform position is reached.
3. Remove the handle from the hand pump.