No.
L8-18
Soft CLA selection
Hunting-prevention function selec-
n1-01
tion
n1-02
Hunting-prevention gain
Speed feedback detection control
n2-01
(AFR) gain
Speed feedback detection control
n2-02
(AFR) time constant
Speed feedback detection control
n2-03
(AFR) time constant 2
High-slip braking deceleration fre-
n3-01
quency width
n3-02
High-slip braking current limit
n3-03
High-slip braking stop dwell time
n3-04
High-slip braking OL time
n4-07
Integral time of speed estimator
Proportional gain of speed estima-
n4-08
tor
n4-17
Torque adjustment gain
n4-18
Feeder resistance adjustment gain
n5-01
Feed forward control selection
n5-02
Motor acceleration time
n5-03
Feed forward proportional gain
o1-01
Monitor selection
o1-02
Monitor selection after power up
Frequency units of reference set-
o1-03
ting and monitor
Setting unit for frequency parame-
o1-04
ters related to V/f characteristics
o1-05
LCD brightness adjustment
* 1. Not initialized. (Japanese standard specifications: A1-01 = 1, A1-02 = 2)
* 2. The factory setting will change if the control method is changed. The factory settings given above are for V/f without PG control.
* 3. Factory setting depends on the control method (A1-02).
* 4. For V/f with PG control: 1.0
* 5. For Drives with a capacity of 55 kW or more: 2.00
* 6. Setting range and initial setting depend on Drive capacity.
* 7. Setting for 200-240 V class Drives. For 380-480 V class Drives, double the value.
* 8. Factory setting in the parentheses is for 3-wire sequence.
* 9. The contents is ignored if the setting is 0.0.
* 10.E1-13 will have the same value as E1-05 after autotuning.
* 11.If the set value is 0, acceleration will be to the speeds for the acceleration times (C1-01 to C1-08)
* 12.The setting range is 10% to 200% of the Drive rated output. (The value given is for a 200-240 V Class Drive for 0.4 kW.)
-24
10
Table 10.7 User Parameters (Continued)
Factory
Name
Setting
Setting
1
1
1.00
1.00
50
750
5
150
1.0
40
0.100
15
0.8
1.00
0
0.178
1.0
6
1
0
0
3
No.
Name
LOCAL/REMOTE key enable/dis-
o2-01
able
STOP key during control circuit
o2-02
terminal operation
o2-03
User parameter initial value
o2-04
kVA selection
Frequency reference setting
o2-05
method selection
Operation selection when digital
o2-06
operator is disconnected
o2-07
Cumulative operation time setting
Cumulative operation time selec-
o2-08
tion
o2-10
Fan operation time setting
Fault trace/fault history clear func-
o2-12
tion
o3-01
Copy function selection
o3-02
Read permitted selection
T1-00
Motor 1/2 selection
T1-01
Autotuning mode selection
T1-02
Motor output power
T1-03
Motor rated voltage
T1-04
Motor rated current
T1-05
Motor base frequency
T1-06
Number of motor poles
T1-07
Motor base speed
PG pulses per revolution for teach-
T1-08
ing
Factory
Setting
Setting
1
1
0
*6
0
0
0
0
0
0
0
0
0
1
0
0.40
*7
200.0
*6
1.90
60.00
4
1750
600