YASKAWA CIMR-G7U Technical Manual page 205

Hide thumbs Also See for CIMR-G7U:
Table of Contents

Advertisement

Name
Parameter
Number
Display
Torque
Reference at
Previous
Gives the torque reference at the
U2-10
Fault
most recent fault.
Torque
Reference
Input
Terminal
Status at
Shows the input terminal status at
Previous
U2-11
the most recent fault.
Fault
Input Term
Sts
Output
Terminal
Status at
Gives the output terminal status
Previous
U2-12
at the most recent fault.
Fault
Output Term
Sts
Drive
Operation
Status at
Displays the Drive Operation
Previous
U2-13
Status at the most recent fault.
Fault
Inverter
Status
Cumulative
Operation
Time at
Gives the cumulative operation
U2-14
Previous
time at the previous fault.
Fault
Elapsed time
Note The following errors are not included in the error trace: CPF00, 01, 02, 03, UV1, and UV2.
Output Signal
Level During
Description
Multi-Function
Analog Output
No output possible.
User Parameter Tables
Control Methods
Open
Open
Min.
V/f
Loop
Flux
Loop
Unit
V/f
with
Vector
Vector
Vector
PG
1
0.1%
No
No
A
No
-
A
A
A
A
-
A
A
A
A
-
A
A
A
A
1
A
A
A
A
hr
MODBUS
Register
2
A
89H
A
8AH
A
8BH
A
8CH
A
8DH
93
5-