 Parameter Settings for Autotuning
The following parameters must be set before autotuning.
Parameter
Number
T1-00
T1-01
T1-02
T1-03
T1-04
T1-05
-12
4
Table 4.3 Parameter Settings before Autotuning
Name
Display
Display
Motor 1/2
When switching to motor 2 is
selected, set the motor for
*1
selection
which autotuning is to be per-
formed. (This parameter is
ignored if motor 2 is not
Select
selected.)
Motor
1: Motor 1
2: Motor 2
Autotun-
Set the autotuning mode.
ing mode
0: Rotational autotuning
selection
1: Stationary autotuning
2: Stationary autotuning for
Tuning
line-to-line resistance only
Mode Sel
Motor
output
power
Set the output power of the
*5 *7
motor in kilowatts.
Mtr Rated
Power
Motor
rated
voltage
Set the rated voltage of the
*5 *6
motor in volts.
Rated
Voltage
Motor
rated
Set the rated current of the
current
*5 *7
motor in amps.
Rated
Current
Motor
base fre-
Set the base frequency of the
quency
*3 *4 *5 *6
motor in hertz.
Rated Fre-
quency
Data Displays during Autotuning
Setting
Factory
Range
Setting
V/f
1 or 2
1
Yes
2 (V/f)
0 (Vec-
0 to 2
Yes
*4
tor)
0.00 to
0.40 kW
Yes
650.00 kW
*2
0 to
255.0 V
200.0 V
(200-240 V
(200-240
class)
V class)
-
0 to
400.0 V
510.0 V
(380-480
(380-480 V
V class)
class)
0.32 to
*2
Yes
1.90 A
*3
6.40 A
0 to
60.0Hz
-
400.0 Hz
Open-
Open-
V/f with
loop
Flux
loop
PG
Vector
Vector
Vector
1
2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes