Figure 76 Hard disk and bracket screws
Insert screws
Caution: Use only the screws that you removed from the hard disk in the
procedure
"To remove the hard disk" on page
damage the hard disk.
4
Set the hard disk and bracket in the main unit.
5
Press down lightly on the top of the hard disk to ensure that the hard disk bracket is seated
properly.
6
Connect the power cable to the hard disk. Refer to
the cable.
Note: Do not force the cables.
The connectors on the power cable and the Serial ATA cable have a notch that
prevents the cables from being inserted backwards. If the cables do not insert
properly, check that the notch on the hard disk connector is aligned with the
corresponding notch on the cable.
7
Connect the Serial ATA cable to the hard disk. Refer to the figure
the location of the cable.
8
Ensure the fan cable is routed through the cutouts under the hard disk and bracket. Also make
sure that any slack in the fan cable is secured in the clips on the hard disk bracket (see
77 on page
200).
Chapter 24 Replacing an internal component
Insert screws
195. Using other screws may
Figure 73 on page 195
BCM50 Installation and Maintenance Guide
for the location of
Figure 73 on page 195
Figure
199
for