Note: The Startup Profile works only on a BCM50 system that has no keycodes loaded.
After the keycodes are loaded, the Startup Profile does not work. This condition prevents
unintentional overwriting of the parameters of a configured system.
4
Remove the USB storage device from the USB port on the BCM50 or the USB hub.
Note: Make sure the bootup sequence is complete before removing the USB
storage device from the BCM50 system.
5
Connect the 25-pair cable to the RJ-21 telephony connector on the BCM50 main unit.
The Startup Profile is now loaded on your BCM50 system.

Next step

After you have loaded the Startup Profile, you can connect the data networking cables. Refer to
"Completing the initial installation (optional)" on page 149
cables.