To Measure The Insertion Loss From The Analog Device To The Co; Configuring The Ata2 - Nortel BCM50 Installation And Maintenance Manual

Nortel networks telephone system installation and maintenance guide
Table of Contents

Advertisement

Use RECEIVE/600 OHM/HOLD mode on the test set
3
Ensure that the test set connects in parallel to the service line before removing the analog
telephone or the line drops.
4
Remove the single-line telephone.
5
Measure the 1 kHz tone at the far end of the analog port, which is where the analog loop ends
and where the analog device connects.
Note: The tone must be greater than - 10 dB (for example: - 9 dB is acceptable).

To measure the insertion loss from the analog device to the CO

1
Establish a connection to a silent termination on the CO service line with an analog telephone
attached to the ATA2.
2
Make sure the analog port terminates correctly in 600 ohms by:
Replace the analog telephone with the test set
Use TRANSMIT/600 OHM/HOLD mode on the test set
3
Make sure the test set connects in parallel to the service line before removing the analog
telephone or the line drops.
4
Remove the analog telephone.
5
Introduce a 1 kHz tone into the analog line at - 10 dBm, and measure the level at the CO
exchange.
Note: The difference in levels is the transmit loss and must be less than 10 dB
(for example, 9 dB is acceptable).

Configuring the ATA2

Configure the ATA2 using Element Manager or Telset Administration. For detailed configuration
information, refer to the BCM50 Device Configuration Guide
Chapter 11 Installing the analog terminal adapter
(N0027146).
BCM50 Installation and Maintenance Guide