April 2004

Configuring SCAICOMS

Introduction
Table SCAICOMS defines linkset names and assigns them to the appropriate
hardware device. This enables a logical pathway through the EIU to Symposium
Call Center Server.
To update table SCAICOMS
1
Edit the SCAICOMS table by typing table SCAICOMS and pressing Enter.
Result: The > prompt appears.
2
Type add and press Enter.
Result: The LINKSET prompt appears.
3
For LINKSET, type a name for the server in Symposium Call Center Server
as it is known to the switch, then press Enter. The LINKSET name creates
a logical pathway to the server on the EIU.
Result: The LINKSEL prompt appears.
4
Identify the connection type as TCP and press Enter.
Result: The IP_ADDR prompt appears.
5
The IP address entered must match the IP address of the server in
Symposium Call Center Server on the ELAN. To obtain the IP address of
the server in Symposium Call Center Server, follow the procedure in
"Checking the server configuration" on page 81.
Result: The utility prompts you to save the new linkset.
6
Type Y and press Enter.
7
To exit from the table, type quit and press Enter.
Symposium and DMS/MSL-100 Switch Guide