Configuring the switch
To enter and edit data in the tables
If you have entered an incorrect parameter in a table, you can change the
parameter without discarding the parameters that have been entered correctly.
To change an incorrect parameter.
1
Access the table for which you want to edit the incorrect parameter by
typing table <table name> at the prompt (>), and then press Enter.
2
Type CHA at the prompt, and then press Enter. This allows you to step
through each parameter in the table.
3
If each parameter is correct, press Enter. If not, edit the parameter, and
then press Enter.
4
Continue to press Enter until the prompt appears before the incorrect
parameter.
5
Delete the incorrect parameter and enter the correct parameter.
6
To save the changes, type quit, and then press Enter.
7
Press Enter to exit the table.
Printing data in the tables
You might want to refer to information configured in the server logon tables. For
example, you might want to identify, as part of the project management function,
information such as ACDGRP information, RAN and music routes, and
thresholds routes. Print a hard copy of this information during configuration of
the switch to quickly be able to reference the information if you intend to modify
the configuration parameters at a later date.