Configuring Initial Ip Configuration Data On Mgc - Nortel 1000 Installation And Commissioning Manual

Table of Contents

Advertisement

Configuring initial IP configuration data on MGC

Perform a customer backup data dump (installation release)
Procedure 28
Performing a data dump to backup the customer database:
1
Log in to the system.
2
Insert a CF card into the active CP PM Call Server RMD slot to back up
the database.
3
Load the Equipment Data Dump Program (LD 43). At the prompt, enter:
LD 43
.
4
When "EDD000" appears on the terminal, enter:
EDD
CAUTION — Service Interruption
Loss of Data
If the data dump is not successful, do not continue;
contact your technical support organization. A data dump
problem must be corrected before proceeding.
5
When "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" appear on the terminal, enter:
****
The installation is now complete.
Note: Coordinate all Nars/Bars and NRS changes to ensure that your
cutover plan is designed for minimum downtime.
Communication Server 1000E
Installing software on the CS 1000E
Load program.
EDD
Begin the data dump.
Exit program
End of Procedure