Reset; Figure 3-49. Self-Test Screen After Resetting The Switch - Nortel BayStack 410 24T Using Manual

10base-t switch
Table of Contents

Advertisement

Using the BayStack 410-24T 10BASE-T Switch

Reset

The Reset option (accessed from the main menu) allows you to reset a standalone
switch, a specific unit in a stack configuration, or an entire stack without erasing
any configured switch parameters. Resetting the switch takes approximately 5
seconds. During this time, the switch initiates a self-test that comprises various
diagnostic routines and subtests. The LEDs display various patterns to indicate
that the subtests are in progress. The results of the self-test are displayed briefly
(5 or 10 seconds) in the Self-Test screen
Nortel Networks logo screen
Note: The Self-Test screen remains displayed only if the self-test detects a
fatal error.
BayStack 410-24T Self-Test
CPU RAM test
ASIC addressing test
ASIC buffer RAM test
ASIC buffer stack init test
Port internal loopback test
Cascade SRAM test
Fan test
Self-test complete.
Figure 3-49.
Self-Test Screen After Resetting the Switch
Note: The Self-Test screen for a switch that is participating in a stack
configuration includes an additional test:
3-112
(Figure
(Figure
3-50).
... Pass
... Pass
... Pass
... Pass
... Pass
... Pass
... Pass
Cascade SRAM test.
3-49), which is followed by the
309985-B Rev 00

Hide quick links: