  • Page 1 Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A)
  • Page 2 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject...
  • Page 3: Table Of Contents

    10 Gigabit small form factor pluggable transceivers Selecting an XFP 27 Procedure job aid: XFP models 28 NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs 5.1 6 December 2007...
  • Page 4 10GBASE-SR XFP specifications 44 10GBASE-LR/LW XFP specifications 46 10GBASE-ER/EW XFP specifications 47 10GBASE-ZR/ZW XFP specifications 48 Index NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs 5.1 6 December 2007...
  • Page 5: New In This Release

    New in this release The following sections detail what’s new in Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs (NN47205-301) for Release 5.1. • "Features" (page 5) • "Other changes" (page 5) Features See the following section for information about feature changes: New SFPs Release 5.1 supports two new SFPs.
  • Page 6 6 New in this release Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 7: Introduction

    "10 Gigabit small form factor pluggable transceivers" (page 27) • "SFP specifications" (page 33) • "XFP specifications" (page 43) NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs 5.1 6 December 2007...
  • Page 8 8 Introduction Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 9: Safety And Regulatory Information

    • Do not touch anyone who is not grounded. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks "Electrostatic discharge prevention" Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs 5.1 6 December 2007...
  • Page 10: Care Of Fiber Optic Equipment

    flat on a shelf. Frequent overstressing of fiber optic cable causes progressive degeneration that leads to failure. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs 5.1 6 December 2007...
  • Page 11: Fiber Optic Connector Care

    To prevent them from collecting dust, make sure connectors are covered when not in use. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks CAUTION Risk of equipment damage Do not crush fiber optic cable. If fiber optic cable is in the same tray or duct with large, heavy electrical cables, it can be damaged by the weight of the electrical cable.
  • Page 12: Job Aid: Connector Cleaning Tools And Materials

    NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks CAUTION Risk of equipment damage To avoid contamination, optical ports should only be cleaned when there is evidence of contamination or reduced performance, or during their initial installation.
  • Page 13: Cleaning Duplex Connectors

    Each cleaning wand should only be used to clean one optical port. Reconnect the optical connector and check for proper function. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks On removable shroud connectors, hold the shroud on the top and bottom at the letter designation, apply medium pressure, and pull it free from the connector body.
  • Page 14: Product Safety Warnings And Information

    ESD and installation caution messages This section provides electrostatic discharge (ESD) and installation caution messages and translations. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks —End— CAUTION Risk of equipment damage To prevent damage from electrostatic discharge, always wear an antistatic wrist strap connected to an ESD jack.
  • Page 15 NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Product safety warnings and information 15 CAUTION PRECAUCIÓN Riesgo de daño del equipo Para prevenir el daño producido por una descarga electrostática, use siempre una pulsera antiestática conectada a un enchufe ESD.
  • Page 16: Laser Safety Warnings

    16 Safety and regulatory information Laser safety warnings This section provides laser safety warnings and translations. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks CAUTION PRECAUCIÓN Riesgo de daño del equipo Sólo el personal capacitado puede instalar este producto.
  • Page 17 NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Product safety warnings and information 17 WARNING AVERTISSEMENT Risques de blessure oculaire par lumière laser L’équipement de fibres optiques peut émettre une lumière laser ou infrarouge nuisible à vos yeux. Ne regardez jamais en direction de fibres optiques ou d’un port connecteur.
  • Page 18 18 Safety and regulatory information Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 19: Small Form Factor Pluggable Transceivers

    Determine the required media and connector type. Fiber optic cable is required for any reach over 100 m. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs 5.1 6 December 2007...
  • Page 20: Procedure Job Aid: Sfps And Common Applications

    Procedure job aid: SFP models without DDI support SFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. NN47205-301 (324186-A) 01.04 Standard Copyright ©...
  • Page 21: Procedure Job Aid: Sfp Models With Ddi Support

    Procedure job aid: SFP models with DDI support Any Digital Diagnostic Indicating (DDI) SFP can be used in any Ethernet Routing Switch 4500 Series module that supports SFPs. The optical functions of the SFP are supported. Access to the DDI information will be provided in a future release.
  • Page 22: Installing An Sfp

    22 Small form factor pluggable transceivers The following table lists and describes the supported Nortel SFP models with DDI capability. All the optical SFPs use LC connectors. SFP models with DDI capability Model number and connector 1000BASE-T (RJ-45) 1000BASE-BX 1000BASE-LX For specifications, see...
  • Page 23: Procedure Steps

    Remove the dust cover from the optical bore and insert the fiber optic connector. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks CAUTION Risk of equipment damage SFPs are keyed to prevent incorrect insertion. If the SFP resists pressure, do not force it; turn it over, and reinsert it.
  • Page 24: Procedure Job Aid: Locking And Extractor Mechanisms

    The following figure shows the wrap-around latch-type extraction mechanism. To remove the device, push the collar towards the module. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Figure 1 "SFP with bail lock and extraction 24), the SFP still has the bore plug installed. Pull the Ethernet Routing Switch 4500 Series Installation —...
  • Page 25: Removing An Sfp

    Action Disconnect the network fiber cable from the SFP connector. Affix dust covers over the fiber optic bore and connector. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks "Laser safety warnings" (page WARNING Risk of eye injury by laser Fiber optic equipment can emit laser or infrared light that can injure your eyes.
  • Page 26 Store the SFP in a safe place until needed. If you discard the SFP, be sure to dispose of it according to all national laws and regulations. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks ATTENTION —End— Ethernet Routing Switch 4500 Series Installation —...
  • Page 27: Gigabit Small Form Factor Pluggable Transceivers

    Factor Pluggable (XFP) transceivers, and lists some technical specifications for the supported XFP models. Nortel recommends that you only use Nortel qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 28: Ethernet Routing Switch 4500 Series

    Procedure job aid: XFP models XFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow 10 Gigabit Ethernet ports to link with other 10 Gigabit Ethernet ports. Digital diagnostic monitoring (DDM) allows real-time access to device operating parameters. All XFPs come with DDM capability.
  • Page 29: Ethernet Routing Switch 4500 Series

    Apply a light pressure to the XFP until the device clicks and locks into position in the module. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks WARNING Risk of eye injury by laser Fiber optic equipment can emit laser or infrared light that can injure your eyes.
  • Page 30: Ethernet Routing Switch 4500 Series

    Remove an XFP to replace it or to commission it elsewhere. For translations of the following statements, see caution messages" (page 14) NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks —End— "Laser safety warnings" (page Ethernet Routing Switch 4500 Series Installation —...
  • Page 31: Ethernet Routing Switch 4500 Series

    If you discard the XFP, be sure to dispose of it according to all national laws and regulations. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks WARNING Risk of eye injury by laser Fiber optic equipment can emit laser or infrared light that can injure your eyes.
  • Page 32: Ethernet Routing Switch 4500 Series

    32 10 Gigabit small form factor pluggable transceivers Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 33: Ethernet Routing Switch 4500 Series

    • "1000BASE-ZX CWDM SFP specifications" (page 41) SFP labels The Nortel label on a typical SFP contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Ethernet Routing Switch 4500 Series Installation —...
  • Page 34: Ethernet Routing Switch 4500 Series

    The 100BASE-FX SFP provides 100 Mbit/s Ethernet Carrier Sense Multiple Access with Collision Detection (CSMA-CD) connectivity using multimode optical fiber. The part number for this model is AA1419074-E6 This device can be used with the Ethernet Routing Switch 4526FX, 4526T, 4526T-PWR, 4550T, 4550T-PWR, and 4524GT. NN47205-301 (324186-A) 01.04 Standard Copyright ©...
  • Page 35: Ethernet Routing Switch 4500 Series

    The T1 SFP provides full-duplex Fast Ethernet to T1 connectivity. The part number for this model is AA1419075-E6. This device can be used with the Ethernet Routing Switch 4526FX, 4526T, 4526T-PWR, 4550T, 4550T-PWR, and 4524GT. The following table describes the T1 SFP specifications.
  • Page 36: Ethernet Routing Switch 4500 Series

    T1 SFP module and the far-end T1 equipment if the far end has the pinout shown in the following table. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Specification Up to 2874 m over 22 AWG cable. The distance may be reduced when 24 AWG UTP CAT5/5E cable is used.
  • Page 37: Ethernet Routing Switch 4500 Series

    Do this to convert a straight-through cable to a crossover cable. T1 SFP—default settings The Ethernet Routing Switch 4500 Series switches configure the following T1 SFP parameters after the system powered up: • Transmit Line Build Out (TLBO): set according to cable length.
  • Page 38: Nn47205-301 (324186-A) 01.04 Standard

    T1 Tx disabled behavior T1 Transmit AIS The T1 SFP module must be configured to match the parameters of the T1 equipment at the far end. If you must change the parameters, contact Nortel Technical Support. 1000BASE-SX (LC) SFP specifications The 1000BASE-SX SFP provides 1000BASE-SX Gigabit Ethernet connectivity at 850 nm using multimode optical fiber.
  • Page 39: Ethernet Routing Switch 4500 Series

    Link optical power budget Transmitter characteristics Launch power Receiver characteristics Receiver sensitivity Maximum input power NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks 1000BASE-SX (MT-RJ) SFP specifications 39 Specifications Duplex LC • 62.5 µm MMF optic cable • 50 µm MMF optic cable •...
  • Page 40: Ethernet Routing Switch 4500 Series

    Cabling Data rate Line rate (8B/10B code) Operating temperature range Link optical power budget Transmitter characteristics NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Specifications Duplex LC • 50 micrometer (µm) multimode fiber (MMF) • 62.5 µm multimode fiber •...
  • Page 41: Ethernet Routing Switch 4500 Series

    Link optical power budget Transmitter characteristics Launch power Receiver characteristics Receiver sensitivity Maximum input power NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks 1000BASE-ZX CWDM SFP specifications 41 Specifications -4.0 to 1.0 dBm -21 dBm -3.0 dBm CAUTION Risk of equipment damage For the 40 km CWDM SFPs, a minimum attenuation of 4 dB must be present between the transmitter and receiver.
  • Page 42: Ethernet Routing Switch 4500 Series

    42 SFP specifications Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 43: Ethernet Routing Switch 4500 Series

    For more details, see these standards documents. All Nortel XFPs meet or exceed these standards. Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 44: Ethernet Routing Switch 4500 Series

    For more information about the 10GBASE-SR XFP, including test and measurement information, see the IEEE 802.3ae standard. NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Specifications 0.49 x 0.72 x 2.79 inches (in.) 12.5 x 18.35 x 71.1 millimeters (mm)
  • Page 45: Ethernet Routing Switch 4500 Series

    Stressed receiver sensitivity in OMA Receiver electrical 3 dB upper cutoff frequency NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks 10GBASE-SR XFP specifications 45 CAUTION Risk of equipment damage To prevent damage to the optical receiver, ensure that at least 1 dB of attenuation is present between the transmit and receive ports.
  • Page 46: Ethernet Routing Switch 4500 Series

    46 XFP specifications The stressed sensitivity values are for system level BER measurements, which include the effects of CDR circuits. Nortel recommends that you allocate at least 0.4 dB additional margin if you make component level measurements without the effect of CDR circuits.
  • Page 47: Ethernet Routing Switch 4500 Series

    (TDP) Minimum optical modulation amplitude Maximum average launch power of OFF transmitter Minimum extinction ratio Maximum RIN NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks 10GBASE-ER/EW XFP specifications 47 Specifications 1.5 dBm -12.6 dBm -12 dB -10.3 dBm 12.3 GHz...
  • Page 48: Ethernet Routing Switch 4500 Series

    Line rate (nominal) MTBF Distance Link optical power budget Maximum transmitter and dispersion penalty Transmitter characteristics NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks Specifications -21 dB -15.8 dBm to -1.0 dBm 4.0 dBm -14.1 dBm -26 dB -11.3 dBm 12.3 GHz...
  • Page 49: Ethernet Routing Switch 4500 Series

    ER) Maximum average receive power for damage Receiver reflectance (maximum) Receive electrical 3 dB upper cutoff frequency NN47205-301 (324186-A) 01.04 Standard Copyright © 2007, Nortel Networks 10GBASE-ZR/ZW XFP specifications 49 Specifications 1530 to 1565 nm; nominal 1550 nm 30 dB 0 to 4.0 dBm...
  • Page 50: Ethernet Routing Switch 4500 Series

    AA1419032-E5 21, 40 AA1419033-E5 21, 41, AA1419040-E5 21, 41, AA1419043-E6 22 AA1419069-E6 22 AA1419070-E6 22 AA1419074-E6 22, 34 Copyright © 2007, Nortel Networks AA1419075-E6 35 cable crossover 36 straight-through 36 cleaning, handling fiber optic connectors 12 duplex connectors 13 receptacle or duplex devices 13...
  • Page 51: Ethernet Routing Switch 4500 Series

    Index 51 T1 20, 35 XFP specifications 44 Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 52: Ethernet Routing Switch 4500 Series

    52 Index Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 (324186-A) 01.04 Standard 5.1 6 December 2007 Copyright © 2007, Nortel Networks...
  • Page 54: Ethernet Routing Switch 4500 Series

    While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.

This manual is also suitable for:

4548gt4526t4550t4526fx4526t-pwr4550t-pwr ... Show all

Table of Contents