Appendix2 Index

Numerics
15-speed selection (combination with three speeds RL, RM,
RH)(REX signal) .............................................................94, 130
A
Acceleration time, deceleration time setting (Pr. 7, Pr. 8, Pr.
20, Pr. 21, Pr. 44, Pr. 45) ....................................................101
Acceleration/deceleration pattern (Pr. 29)............................105
Actual operation time ...............................................................145
Advanced magnetic flux control (Pr. 71, Pr. 80, Pr. 81, Pr. 89,
Pr. 800).....................................................................................78
Alarm output (LF signal) ..................................136, 203, 218, 248
Analog input fault (E.AIE) ........................................................278
Analog input selection(Pr. 73, Pr. 267) .................................167
Applied motor (Pr. 71, Pr. 450)...............................................110
Automatic restart after instantaneous power failure/flying start
(Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr.
299, Pr. 611)..........................................................................153
Avoid mechanical resonance points (frequency jumps) (Pr. 31
to Pr. 36) ..................................................................................89
B
Base frequency, voltage (Pr. 3, Pr. 19, Pr. 47)......................90
Basic operation (factory setting)...............................................51
Bias and gain of frequency setting voltage (current) (Pr. 125,
Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905)) ................170
Brake opening completion signal (BRI signal) .............126, 130
Brake opening request (BOF signal) .............................126, 136
Brake sequence fault (E.MB4 to 7)................................126, 277
Brake sequence function (Pr. 278 to Pr. 283, Pr. 292).......126
Brake transistor alarm detection (E.BE) ...............................275
Buzzer control (Pr. 990)...........................................................261
C
Cables and wiring length ...........................................................17
Change the control method (Pr. 80, Pr. 81, Pr. 800) ............76
Change the parameter setting value .......................................53
Changing the control logic.........................................................23
Checking the inverter and converter modules .....................291
Cleaning .....................................................................................292
Command source switchover (turning ON X67 makes Pr. 338
and Pr. 339 commands valid) (X67 signal) ..............130, 193
Communication EEPROM write selection (Pr. 342) ...........206
Communication option fault (E.OP1).....................................276
Condition selection of function validity by second function
selection signal (RT signal).................................................133
Connection of a DC reactor (FR-HEL) ....................................33
Connection of a dedicated external brake resistor................29
Connection of the brake unit (FR-BU2)...................................31
Connection of the high power factor converter (FR-HC)......32
Connection of the power regeneration common converter
(FR-CV) ....................................................................................33
Connection to the PU connector ..............................................27
Converter Output Voltage .......................................................145
Converter output voltage peak value.....................................145
Cooling fan operation selection (Pr. 244) .............................248
Cooling system types for inverter panel..................................10
CPU error (E.5, E.6, E. 7, E.CPU) .........................................277
Cumulative energization time .................................................145
Cumulative power.....................................................................145
Current average value monitor signal (Pr. 555 to Pr. 557) 254
Current average value monitor signal (Y93 signal).....136, 254
D
Daily and periodic inspection ..................................................289
Daily inspection.........................................................................288
Dancer control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)..............239
DC injection brake (Pr. 10 to Pr. 12) .....................................120
Detection of output frequency
(SU, FU signal, Pr. 41 to Pr. 43) ........................................140
312
Display of the life of the inverter parts
(Pr. 255 to Pr. 259) ...................................................... 249, 290
Droop control (Pr. 286 to Pr. 287) ......................................... 245
During PID control activated (PID signal)............. 136, 232, 239
During retry (Y64 signal) ................................................. 136, 161
E
Earth (ground) fault detection at start (Pr. 249)................... 163
Easy operation mode setting (easy setting mode) ............... 52
Electronic thermal O/L relay pre-alarm (TH)................ 108, 272
Electronic thermal O/L relay pre-alarm (THP signal).. 108, 136
Electronic Thermal Relay Function Load Factor................. 145
Extended parameter display and user group function (Pr. 160,
Pr. 172 to Pr. 174)................................................................ 179
External thermal relay input (OH signal) ...................... 108, 130
External thermal relay operation (E.OHT).................... 108, 276
External/NET operation switchover (turning ON X66 selects
NET operation) (X66 signal)....................................... 130, 190
F
Fan alarm (FN) ................................................................. 248, 272
Fan fault output (FAN signal) ......................................... 136, 248
Fault or alarm indication.................................................. 145, 264
Fault output (ALM signal)................................................ 136, 139
Fault output 3 (power-OFF signal) (Y91 signal) .......... 136, 139
Faults history (E.---) ................................................................. 264
Fin overheat (E.FIN) ................................................................ 275
Forward rotation command (assigned to STF terminal (Pr.
178) only) (STF signal)................................................ 130, 134
Free parameter (Pr. 888, Pr. 889) ......................................... 256
Frequency setting value .................................................. 145, 150
Front cover .................................................................................... 5
G
General-purpose magnetic flux vector control (Pr. 71, Pr. 80,
Pr. 81, Pr. 800) ....................................................................... 81
H
Heatsink overheat pre-alarm (FIN signal) .................... 136, 275
High speed operation command (RH signal)................. 94, 130
I
Initial settings and specifications of RS-485 communication
(Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549) ................. 202
Input phase loss (E.ILF) .................................................. 163, 275
Input terminal function selection(Pr. 178 to Pr. 189) .......... 130
Input Terminal Status .............................................................. 145
Input/output phase loss protection selection
(Pr. 251, Pr. 872).................................................................. 163
Inrush current limit circuit fault (E.IOH)................................. 277
Insulation resistance test using megger ............................... 300
Internal board fault(E.PE2) ..................................................... 277
Internal circuit fault (E.13)....................................................... 278
Inverter I/O Terminal Monitor ......................................... 145, 148
Inverter installation environment................................................ 8
Inverter operation ready (RY signal) ............................. 136, 138
Inverter output shutoff signal (MRS signal, Pr. 17)............. 132
Inverter overload trip (electronic thermal relay function)
(E.THT) .......................................................................... 108, 274
Inverter placement ..................................................................... 11
Inverter replacement................................................................ 295
Inverter reset (Err.)........................................................... 268, 270
Inverter reset (RES signal) ............................................. 130, 268
Inverter run enable signal(FR-HC/FR-CV connection) (X10
signal)............................................................................. 121, 130
Inverter running (RUN signal) ........................................ 136, 138
Inverter thermal load factor..................................................... 145
Inverter-generated noises and their reduction techniques .. 38