Appendix3 Index - Mitsubishi Electric FR-D720-0.1K Instruction Manual

Hide thumbs Also See for FR-D720-0.1K:
Table of Contents

Advertisement

n
Appendix3
Numerics
15-speed selection (REX signal) ..................................... 90, 114
A
Acceleration time, deceleration time setting (Pr. 7, Pr. 8, Pr.
20, Pr. 21, Pr. 44, Pr. 45)...................................................... 97
Acceleration/deceleration pattern (Pr. 29) ........................... 100
Actual operation time............................................................... 129
Alarm output (LF signal) ................................. 120, 183, 199, 227
Analog input fault (E.AIE) ....................................................... 264
Analog input selection (Pr. 73, Pr. 267) ............................... 151
Applied motor (Pr. 71, Pr. 450).............................................. 104
Automatic restart after instantaneous power failure/flying start
(Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr.
299, Pr. 611) ......................................................................... 137
Avoid mechanical resonance points (frequency jumps) (Pr. 31
to Pr. 36).................................................................................. 85
B
Base frequency, voltage (Pr. 3, Pr. 19, Pr. 47) ..................... 86
Basic operation (factory setting).............................................. 55
Bias and gain of frequency setting voltage (current) (Pr. 125,
Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905)) ............... 154
Bias and gain of the built-in frequency setting potentiometer
(C22 (Pr. 922) to C25 (Pr. 923))........................................ 242
Brake transistor alarm detection (E.BE)............................... 262
Built-in potentiometer switching (Pr. 146) ............................ 241
Buzzer control (Pr. 990).......................................................... 240
C
Cables and wiring length .......................................................... 17
Changing the control logic ........................................................ 22
Changing the parameter setting value ................................... 57
Checking the inverter and converter modules..................... 277
Cleaning .................................................................................... 278
Command source switchover (turning ON X67 makes Pr. 338
and Pr. 339 commands valid) (X67 signal).............. 114, 175
Communication EEPROM write selection (Pr. 342)........... 186
Condition selection of function validity by second function
selection signal (RT signal) ................................................ 117
Connection of a DC reactor (FR-HEL) ................................... 35
Connection of a dedicated external brake resistor (MRS type,
MYS type, FR-ABR) .............................................................. 31
Connection of the brake unit (FR-BU2).................................. 33
Connection of the high power factor converter (FR-HC) ..... 34
Connection of the power regeneration common converter
(FR-CV) ................................................................................... 35
Connection to the PU connector ............................................. 29
Control circuit terminal .............................................................. 20
Converter output voltage ........................................................ 129
Converter output voltage peak value .................................... 129
Cooling fan operation selection (Pr. 244)............................. 227
Cooling system types for inverter panel ................................. 10
CPU fault (E.5, E.CPU)........................................................... 264
Cumulative energization time................................................. 129
Cumulative power .................................................................... 129
Current average value monitor signal (Pr. 555 to Pr. 557) 233
Current average value monitor signal (Y93 signal) .... 120, 233
D
Daily and periodic inspection ................................................. 275
Daily inspection ........................................................................ 274
Dancer control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134) ............. 219
DC injection brake (Pr. 10 to Pr. 12)..................................... 110
Detection of output frequency
(SU, FU signal, Pr. 41 to Pr. 43)........................................ 124
Index
Display of the life of the inverter parts
(Pr. 255 to Pr. 259).......................................................228, 276
During PID control activated (PID signal) .............120, 211, 219
During retry (Y64 signal) .................................................120, 145
E
Earth (ground) fault detection at start (Pr. 249) ...................147
Easy operation mode setting (easy setting mode) ................56
Electronic thermal O/L relay pre-alarm (THP signal)..101, 120
Electronic thermal relay function load factor ........................129
Electronic thermal relay function pre-alarm (TH).........101, 258
EMC measures ...........................................................................40
Exhibiting the best performance for the motor (offline auto
tuning) (Pr. 71, Pr. 80, Pr. 82 to Pr. 84, Pr. 90, Pr. 96) ..106
Extended parameter display (Pr. 160) ..................................163
External thermal relay input (OH signal).......................101, 114
External thermal relay operation (E.OHT) ....................101, 263
External/NET operation switchover (turning ON X66 selects
NET operation) (X66 signal) .......................................114, 173
F
Fan alarm (FN)..................................................................227, 259
Fan fault output (FAN signal)..........................................120, 227
Fault or alarm indication ..................................................129, 250
Fault output (ALM signal) ................................................120, 123
Fault output 3 (power-OFF signal) (Y91 signal) ..........120, 123
Faults history (E.---) .................................................................250
Fin overheat (E.FIN).................................................................261
Forward rotation command (assigned to STF terminal (Pr.
178) only) (STF signal) ................................................114, 118
Free parameter (Pr. 888, Pr. 889) .........................................235
Frequency setting value ..................................................129, 134
Front cover.....................................................................................5
G
General-purpose magnetic flux vector control
(Pr. 71, Pr. 80).........................................................................76
H
Harmonic suppression guideline in Japan..............................43
Heatsink overheat pre-alarm (FIN signal).....................120, 261
High speed operation command (RH signal) .................90, 114
I
Initial settings and specifications of RS-485 communication
(Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549) .................182
Input phase loss (E.ILF) ..................................................147, 262
Input terminal function selection (Pr. 178 to Pr. 182) .........114
Input Terminal Status...............................................................129
Input/output phase loss protection selection
(Pr. 251, Pr. 872) ..................................................................147
Inrush current limit circuit fault (E.IOH) .................................264
Insulation resistance test using megger ...............................285
Inverter I/O Terminal Monitor..........................................129, 132
Inverter installation environment ................................................8
Inverter operation ready (RY signal) .............................120, 122
Inverter output shutoff signal (MRS signal, Pr. 17) .............116
Inverter overload trip (electronic thermal relay function)
(E.THT)...........................................................................101, 261
Inverter placement......................................................................11
Inverter reset (Err.) ...........................................................254, 257
Inverter reset (RES signal)..............................................114, 254
Inverter run enable signal (FR-HC/FR-CV connection) (X10
signal) .............................................................................111, 114
Inverter running (RUN signal).........................................120, 122
Inverter thermal load factor .....................................................129
299