Mitsubishi Electric FR-E700 Instruction Manual page 74

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
C0
FM terminal calibration
(900)
∗7
C1
AM terminal calibration
(901)
∗7
C2
Terminal 2 frequency setting bias
(902)
frequency
∗7
C3
Terminal 2 frequency setting bias
(902)
∗7
125
Terminal 2 frequency setting gain
(903)
frequency
∗7
C4
Terminal 2 frequency setting gain
(903)
∗7
C5
Terminal 4 frequency setting bias
(904)
frequency
∗7
C6
Terminal 4 frequency setting bias
(904)
∗7
126
Terminal 4 frequency setting gain
(905)
frequency
∗7
C7
Terminal 4 frequency setting gain
(905)
∗7
C22 to C25
Parameter for manufacturer setting. Do not set.
(922 to 923)
990
PU buzzer control
991
PU contrast adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
Pr.CH
Initial value change list
∗1
Differ according to capacities.
6%: FR-E740-026 or less, FR-E720S-050 or less
4%: FR-E740-040 to 095, FR-E720S-080 and 110
3%: FR-E740-120 and 170
2%: FR-E740-230 and 300
∗2
Differ according to capacities.
5s: FR-E740-095 or less, FR-E720S-110 or less
10s: FR-E740-120 and 170
15s: FR-E740-230 and 300
∗3
Differ according to capacities.
6%: FR-E720S-008 and 015
4%: FR-E740-016 to 170, FR-E720S-030 to 110
2%: FR-E740-230 and 300
∗4
Write is disabled in the communication mode (network operation mode) from the PU connector.
∗5
The initial value differs according to the voltage class. (200V class/400V class)
∗6
The range differs according to the Pr. 71 setting.
∗7
The parameter number in parentheses is the one for use with the operation panel (PA02) for the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
∗8
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication. (Refer to
page 202 for RS-485 communication) Note that when using a three-phase power input specification model, Pr.345 and Pr.346 are set back to initial values.
∗9
Available only for the three-phase power input specification model.
70
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
151
151
0 to 400Hz
0.01Hz
0Hz
170
0 to 300%
0.1%
0%
170
0 to 400Hz
0.01Hz
50Hz
170
0 to 300%
0.1%
100%
170
0 to 400Hz
0.01Hz
0Hz
170
0 to 300%
0.1%
20%
170
0 to 400Hz
0.01Hz
50Hz
170
0 to 300%
0.1%
100%
170
0, 1
1
1
261
0 to 63
1
58
261
0, 1
1
0
262
0, 1
1
0
262
0, 1
1
0
264
263
Customer
Parameter
Remarks
Setting
C0
(900)
C1
(901)
C2
(902)
C3
(902)
125
(903)
C4
(903)
C5
(904)
C6
(904)
126
(905)
C7
(905)
C22 to C25
Parameter for manufacturer setting. Do not set.
(922 to 923)
990
991
Pr.CL
ALLC
Er.CL
Pr.CH
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
5C
DC
1
5D
DD
1
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
5A
DA
9
5B
DB
9
FC
FC
F4
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
×
×
×
×
×
×
×
×
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e740ec

Table of Contents