PU/External combined operation mode 1 (setting "3")
Three-phase AC
power supply
Forward rotation start
Reverse rotation start
(7)
PU/External combined operation mode 2 (setting "4")
R/L1
Three-phase AC
S/L2
power supply
T/L3
10
Frequency setting
2
potentiometer
5
Operation panel
Selection of operation mode and operation location
Inverter
R/L1
U
S/L2
V
T/L3
W
STF
STR
PC
Operation panel
Set frequency
Inverter
U
Motor
V
W
,
Select the PU/External combined operation mode 1
when
applying
operation panel or parameter unit (FR-PU04/FR-
PU07) and inputting the start command with the
external start switch.
Select "3" for Pr. 79. You cannot change to the other
operation mode.
When a frequency is applied from the external signal
by multi-speed setting, it has a higher priority than the
frequency command from the PU. When AU is ON,
the command signal to terminal 4 is used.
Motor
Select the PU/External combined operation mode 2 when
applying
frequency
potentiometer, multi-speed or JOG signal and inputting the
start command by key operation of the operation panel or
parameter unit (FR-PU04/FR-PU07).
Select "4" for Pr. 79. You cannot change to the other
operation mode.
frequency
command
from
command
from
the
external
the
4
187