Monitor Display Selection Of Du/Pu And Terminal Am (Pr. 52, Pr.158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564) - Mitsubishi Electric FR-E700 Instruction Manual

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

4.12.2 Monitor display selection of DU/PU and terminal AM
(Pr. 52, Pr.158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)
The monitor to be displayed on the main screen of the control panel and parameter unit (FR-PU04/FR-PU07) can be
selected.
In addition, signal to be output from the terminal AM (analog voltage output) can be selected.
Parameter
Name
Number
DU/PU main display data
52 ∗
selection
AM terminal function
158 ∗
selection
170
Watt-hour meter clear
171
Operation hour meter clear
Monitor decimal digits
268 ∗
selection
Energization time carrying-
563
over times
Operating time carrying-
564
over times
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 179)
* The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write selection.
(1)
Monitor description list (Pr. 52)
Set the monitor to be displayed on the operation panel and parameter unit (FR-PU04/FR-PU07) in Pr. 52 DU/PU main
display data selection .
Set the monitor to be output to the terminal AM (analog voltage output) in Pr. 158 AM terminal function selection .
Refer to the following table and set the monitor to be displayed. (The monitor marked × cannot be selected.)
Types of Monitor
Unit
Output frequency
0.01Hz
Output current
0.01A
Output voltage
0.1V
Fault display
Frequency setting
0.01Hz
value
Motor torque
0.1%
Converter output
0.1V
voltage
Monitor display and monitor output signal
Initial Value
0
(output
frequency)
1
(output
frequency)
9999
9999
9999
0
0
Pr. 52 Setting
Operation
PU
Pr.158 (AM)
panel
main
Setting
LED
monitor
0/100
1
0/100
2
0/100
3
×
0/100
∗1
5
5
∗1
7
7
∗1
8
8
Setting Range
Select the monitor to be displayed on the
0, 5, 7 to 12, 14, 20,
operation panel and parameter unit.
23 to 25, 52 to 57,
Refer to the following table for monitor
61, 62, 100
description.
1 to 3, 5, 7 to 12,
14, 21, 24, 52, 53,
Select the monitor output to terminal AM.
61, 62
0
Set "0" to clear the watt-hour meter monitor.
Set the maximum value when monitoring from
10
communication to 0 to 9999kWh.
Set the maximum value when monitoring from
9999
communication to 0 to 65535kWh.
Set "0" in the parameter to clear the operation
0, 9999
time monitor.
Setting 9999 does not clear.
0
Displayed as integral value
1
Displayed in 0.1 increments.
9999
No function
The numbers of cumulative energization time
0 to 65535
monitor exceeded 65535h is displayed.
(reading only)
(Reading only)
0 to 65535
The numbers of operation time monitor
(reading only)
exceeded 65535h is displayed. (Reading only)
Terminal AM
Full Scale Value
Pr. 55
Displays the inverter output frequency.
Displays the inverter output current
Pr. 56
effective value.
200V class 400V
Displays the inverter output voltage.
400V class 800V
Displays 8 past faults individually.
Pr. 55
Displays the set frequency.
Displays the motor torque in % on the
Rated torque of the
assumption that the rated motor torque is
applied motor ×2
100%.
(Displays 0% during V/F control)
200V class 400V
Displays the DC bus voltage value.
400V class 800V
Description
Description
145
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e740ec

Table of Contents