No.
Item
6
Inverter reset
Fault definition all
7
clear
Parameter clear
8
All clear
9
Parameter
10
Link parameter
11
expansion setting
Second parameter
changing
12
(instruction code
HFF = 1, 9)
Refer to page 208 for data format (A, A1, A2, B, C, D, E, E1, E2)
REMARKS
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or all
clear is performed.
Example) When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station 0
Computer Send Data
1)
ENQ 00 FF 0 01 82
2)
ENQ 00 EC 0 01 7E
3)
ENQ 00 5E 0 0F
4)
ENQ 00 60 0 FB
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from 1) again.
Instruction
Read/
Write
Code
H9696: Inverter reset
As the inverter is reset at start of communication by the
computer, the inverter cannot send reply data back to the
computer.
Write
HFD
H9666: Inverter reset
When data is sent normally, ACK is returned to the computer
and then the inverter is reset.
Write
HF4
H9696: Faults history batch clear
All parameters return to the initial values.
Whether to clear communication parameters or not can be
selected according to data. ( : Clear, ×: Not clear)
Refer to page 54 for parameter clear, all clear, and communication
parameters.
Clear Type
Parameter clear
Write
HFC
All parameter clear
∗ Note that when using a three-phase power input specification model,
Pr.345 and Pr.346 are set back to initial values.
When clear is executed for H9696 or H9966, communication-
related parameter settings also return to the initial values. When
resuming operation, set the parameters again.
Executing clear will clear the instruction code HEC, HF3, and HFF
settings.
Read
H00 to H63
Refer to the instruction code (Refer to page 54) and write and/or
read parameter values as required.
When setting Pr. 100 and later, link parameter extended setting
must be set.
Data format of Pr. 37 read and write is E2 and A2
Write
H80 to HE3
Parameter description is changed according to the H00 to H09
Read
H7F
setting.
For details of the settings, refer to the parameter instruction code
Write
HFF
(Refer to page 54).
Setting calibration parameter ∗1
H00: Frequency ∗2
Read
H6C
H01: Parameter-set analog value
H02: Analog value input from terminal
∗1
Refer to the list of calibration parameters on the next page for
calibration parameters.
Write
HEC
∗2
The gain frequency can also be written using Pr. 125 (instruction code:
H99) or Pr. 126 (instruction code: H9A).
Inverter Send Data
ACK 00
Set "H01" to the expansion link parameter.
ACK 00
Set "H01" to second parameter changing.
STX 00 0000 ETX 25
C3 (Pr. 902) is read. 0% is read.
STX 00 0000 ETX 25
C6 (Pr. 904) is read. 0% is read.
Communication operation and setting
Data Definition
Data
Communication Pr.
H9696
H5A5A
H9966
H55AA
Description
Number of
Data Digits
(Format)
4 digits
(A, C/D)
4 digits
(A, D)
4 digits
(A, C/D)
×∗
4 digits
(A, C/D)
×∗
4 digits
(B, E/D),
6 digits
(B, E2/D)
4 digits
(A, C/D),
6 digits
(A2, C/D)
2 digits
(B, E1/D)
2 digits
(A1, C/D)
2 digits
(B, E1/D)
2 digits
(A1, C/D)
215