Mitsubishi Electric FR-E700 Instruction Manual page 150

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Types of Monitor
Unit
Inverter thermal load
0.1%
factor
∗1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU04/FR-PU07).
∗2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
When the operation panel is used, the time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is added up from 0.
∗3
Actual operation time is not accumulated when the cumulative operation time is less than 1h until turning off of the power supply.
∗4
When using the parameter unit (FR-PU04/FR-PU07), "kW" is displayed.
∗5
Since the panel display of the operation panel is 4 digits in length, the monitor value of more than "9999" is displayed "----".
∗6
Larger thermal value between the motor thermal and transistor thermal is displayed.
A value other than 0% is displayed if the surrounding air temperature (heatsink temperature) is high even when the inverter is at a stop.
REMARKS
By setting "0" in Pr. 52, the monitoring of output speed to fault display can be selected in sequence by
When the operation panel is used, the displayed units are Hz and A only and the others are not displayed.
The monitor set in Pr. 52 is displayed in the third monitor position. However, change the output current monitor for the motor
load factor.
Initial Value
∗The monitor displayed at powering on is the first monitor. Display the monitor you want to display on the first monitor and hold
down
for 1s. (To return to the output frequency monitor, hold down
monitor.)
Power-on monitor (first monitor)
Output frequency monitor
Example)When Pr. 52 is set to "20" (cumulative energization time), the monitor is displayed on the operation panel as described
below.
Power-on monitor (first monitor)
Output frequency monitor
(2)
Display set frequency during stop
(Pr. 52)
When "100" is set in Pr. 52, the set frequency
and output frequency are displayed during stop
and operation respectively. (LED of Hz flickers
during stop and is lit during operation.)
REMARKS
During an error, the output frequency at error occurrence appears.
During MRS signal is ON, the values displayed are the same as during a stop.
During offline auto tuning, the tuning status monitor has priority.
Monitor display and monitor output signal
Pr. 52 Setting
Operation
PU
Pr.158 (AM)
panel
main
Setting
LED
monitor
62
62
Second monitor
Output current monitor
Second monitor
Output current monitor
Output frequency
Output current
Output voltage
Fault display
The set frequency displayed indicates the frequency to be output when the start
command is ON. Different from the frequency setting displayed when Pr. 52 = "5",
the value based on maximum/minimum frequency and frequency jump is displayed.
Terminal AM
Full Scale Value
Thermal relay
Transistor thermal heat cumulative value is
operation level
displayed.
(Inverter overload trip (E.THT) at 100%)
(100%)
for 1s after displaying the output frequency
Third monitor
With fault
Output voltage monitor
Third monitor
With fault
Cumulative energization time monitor
0
During
During stop
running/stop
Output
frequency
frequency∗
Output current
Output voltage
Fault display
Description
.
Fault monitor
Fault monitor
Pr. 52
100
During
running
Set
Output
frequency
147
4