Mitsubishi Electric FR-E700 Instruction Manual page 72

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
313
DO0 output selection
314
DO1 output selection
315
DO2 output selection
316
DO3 output selection
317
DO4 output selection
318
DO5 output selection
319
DO6 output selection
320
RA1 output selection
321
RA2 output selection
322
RA3 output selection
323
AM0 0V adjustment
324
AM1 0mA adjustment
329
Digital input unit selection
Communication operation command
338
source
Communication speed command
339
source
340
Communication startup mode selection
Communication EEPROM write
342
selection
343
Communication error count
345
DeviceNet address
346
DeviceNet baud rate
349
Communication reset selection
387
Initial communication delay time
388
Send time interval at heart beat
389
Minimum sending time at heart beat
390
% setting reference frequency
391
Receive time interval at heart beat
392
Event driven detection width
450
Second applied motor
495
Remote output selection
496
Remote output data 1
497
Remote output data 2
Communication error execution waiting
500
time
Communication error occurrence count
501
display
Stop mode selection at communication
502
error
66
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0, 1, 3, 4, 7, 8, 11 to 16,
1
9999
20, 25, 26, 46, 47, 64,
1
9999
90, 91, 93, 95, 96, 98,
1
9999
99, 100, 101, 103,
1
9999
104, 107, 108,
1
9999
111 to 116, 120, 125,
1
9999
126, 146, 147, 164,
190, 191, 193, 195,
1
9999
196, 198, 199, 9999
0, 1, 3, 4, 7, 8, 11 to 16,
1
0
20, 25, 26, 46, 47, 64,
1
1
90, 91, 95, 96, 98, 99,
1
4
9999
900 to 1100%
1%
1000
900 to 1100%
1%
1000
0, 1, 2, 3
1
1
0, 1
1
0
193
0, 1, 2
1
0
193
0, 1, 10
1
0
192
0, 1
1
0
206
1
0
218
0 to 4095
1
63
0 to 4095
1
132
0, 1
1
0
0 to 120s
0.1s
0s
0 to 999.8s
0.1s
0s
0 to 999.8s
0.1s
0.5s
1 to 400Hz
0.01Hz
50Hz
0 to 999.8s
0.1s
0s
0.00 to 163.83%
0.01%
0%
0, 1, 9999
1
9999
110
0, 1, 10, 11
1
0
143
0 to 4095
1
0
143
0 to 4095
1
0
143
0 to 999.8s
0.1s
0
0
1
0
203,
0, 1, 2, 3
1
0
218
Customer
Parameter
Remarks
Setting
313
314
315
316
317
318
319
320
321
322
323
324
329
338
339
340
342
343
345
346
349
387
388
389
390
391
392
450
495
496
497
500
501
502
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
0D
8D
3
0E
8E
3
0F
8F
3
10
90
3
11
91
3
12
92
3
13
93
3
14
94
3
15
95
3
16
96
3
17
97
3
18
98
3
1D
9D
3
26
A6
3
27
A7
3
28
A8
3
2A
AA
3
2B
AB
3
2D
AD
3
2E
AE
3
31
B1
3
57
D7
3
58
D8
3
59
D9
3
5A
DA
3
5B
DB
3
5C
DC
3
32
B2
4
5F
DF
4
60
E0
4
61
E1
4
00
80
5
01
81
5
02
82
5
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
∗8
∗8
∗8
∗8
∗8
∗8
×
×
×
∗8
∗8
∗8
∗8
∗8
∗8
4
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e740ec

Table of Contents