Motor Or Machine Is Making Abnormal Acoustic Noise; Inverter Generates Abnormal Noise; Motor Generates Heat Abnormally - Mitsubishi Electric FR-E700 Instruction Manual

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

5.5.2

Motor or machine is making abnormal acoustic noise

Check
points
Input
signal
Disturbance due to EMI when frequency command is
Parameter
given from analog input (terminal 2, 4).
Setting
No carrier frequency noises (metallic noises) are
generated.
Resonance occurs. (output frequency)
Parameter
Resonance occurs. (carrier frequency)
Setting
Auto tuning is not performed under Advanced magnetic
flux vector control or General-purpose magnetic flux
vector control.
Gain adjustment during PID control is insufficient.
Others
Mechanical looseness
Operating with output phase loss
Motor
Contact the motor manufacturer.
5.5.3

Inverter generates abnormal noise

Check
points
Fan cover was not correctly installed when a cooling fan
Fan
was replaced.
5.5.4

Motor generates heat abnormally

Check
points
Motor fan is not working
Motor
(Dust is accumulated.)
Phase to phase insulation of the motor is insufficient.
Main
The inverter output voltage (U, V, W) are unbalanced.
Circuit
Parameter
The Pr. 71 Applied motor setting is wrong.
Setting
Motor current is large.
Possible Cause
Possible Cause
Possible Cause
Check first when you have some troubles
Countermeasures
Take countermeasures against EMI.
Increase the Pr. 74 Input filter time constant if steady
operation cannot be performed due to EMI.
In the initial setting, Pr. 240 Soft-PWM operation selection is
enabled to change motor noise to an unoffending
complex tone. Therefore, no carrier frequency noises
(metallic noises) are generated.
Set Pr. 240 = "0" to disable this function.
Set Pr. 31 to Pr. 36 (Frequency jump).
When it is desired to avoid resonance attributable to the
natural frequency of a mechanical system, these
parameters allow resonant frequencies to be jumped.
Change Pr. 72 PWM frequency selection setting.
Changing the PWM carrier frequency produces an effect
on avoiding the resonance frequency of a mechanical
system or a motor.
Perform offline auto tuning.
To stabilize the measured value, change the proportional
band (Pr. 129) to a larger value, the integral time (Pr. 130)
to a slightly longer time, and the differential time (Pr. 134)
to a slightly shorter time.
Check the calibration of set point and measured value.
Adjust machine/equipment so that there is no
mechanical looseness.
Check the motor wiring.
Countermeasures
Install a fan cover correctly.
Countermeasures
Clean the motor fan.
Improve the environment.
Check the insulation of the motor.
Check the output voltage of the inverter.
Check the insulation of the motor.
Check the Pr. 71 Applied motor setting.
Refer to "5.5.11 Motor current is too large"
Refer
to
page
38
169
165
89
165
112
232
Refer
to
page
294
Refer
to
page
5
289
110
284
281

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e740ec

Table of Contents