Parameter list
Func-
Parameter
Name
tion
503
Maintenance timer
Maintenance timer alarm output set
504
time
Frequency command sign selection
541
(CC-Link)
Communication station number (CC-
542
Link)
543
Baud rate (CC-Link)
544
CC-Link extended setting
547
USB communication station number
USB communication check time
548
interval
549
Protocol selection
NET mode operation command source
550
selection
PU mode operation command source
551
selection
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
—
563
Energization time carrying-over times
—
564
Operating time carrying-over times
—
571
Holding time at a start
—
611
Acceleration time at a restart
—
645
AM 0V adjustment
—
653
Speed smoothing control
Regeneration avoidance frequency
—
665
gain
—
800
Control method selection
—
859
Torque current
872
Input phase loss protection selection
∗9
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance compensation
885
frequency limit value
886
Regeneration avoidance voltage gain
888
Free parameter 1
889
Free parameter 2
68
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 (1 to 9998)
1
0
253
0 to 9998, 9999
1
9999
253
0, 1
1
0
—
1 to 64
1
1
—
0 to 4
1
0
—
0, 1, 12, 14, 18
1
0
—
0 to 31
1
0
231
0 to 999.8s, 9999
0.1s
9999
231
0, 1
1
0
218
0, 2, 9999
1
9999
193
2 to 4, 9999
1
9999
193
0.1 to 1.0s
0.1s
1s
254
0 to 20s
0.1s
0s
254
Rated
0 to 500A
0.01A
inverter
254
current
(0 to 65535)
1
0
145
(0 to 65535)
1
0
145
0 to 10s, 9999
0.1s
9999
104
0 to 3600s, 9999
0.1s
9999
153
970 to 1200
1
1000
151
0 to 200%
0.1%
0
166
0 to 200%
0.1%
100
246
76, 78,
20, 30
1
20
81
0 to 500A (0 to ****) ,
0.01A (1)
9999
112
∗6
9999
∗6
0, 1
1
1
163
0, 1, 2
1
0
246
400VDC/
300 to 800V
0.1V
246
780VDC
∗5
0 to 10Hz, 9999
0.01Hz
6Hz
246
0 to 200%
0.1%
100%
246
0 to 9999
1
9999
256
0 to 9999
1
9999
256
Customer
Parameter
Remarks
Setting
503
504
541
542
543
544
547
548
549
550
551
555
556
557
563
564
571
611
645
653
665
800
859
872
882
883
885
886
888
889
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
03
83
5
04
84
5
29
A9
5
2A
AA
5
2B
AB
5
2C
AC
5
2F
AF
5
30
B0
5
31
B1
5
32
B2
5
33
B3
5
37
B7
5
38
B8
5
39
B9
5
3F
BF
5
40
C0
5
47
C7
5
0B
8B
6
2D
AD
6
35
B5
6
41
C1
6
×
00
80
8
×
3B
BB
8
48
C8
8
52
D2
8
53
D3
8
55
D5
8
56
D6
8
58
D8
8
59
D9
8
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
×
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
×
×
×
×
×
×
×
×
4
×
×
×
×