Parameter list
Func-
Parameter
Name
tion
—
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
—
37
Speed display
—
40
RUN key rotation direction selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
—
59
Remote function selection
—
60
Energy saving control selection
61
Reference current
62
Reference value at acceleration
63
Reference value at deceleration
—
65
Retry selection
Stall prevention operation reduction
—
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
—
70
Special regenerative brake duty
—
71
Applied motor
—
72
PWM frequency selection
—
73
Analog input selection
56
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
121,
0, 1, 2
1
0
153
0 to 400Hz, 9999
0.01Hz
9999
89
0 to 400Hz, 9999
0.01Hz
9999
89
0 to 400Hz, 9999
0.01Hz
9999
89
0 to 400Hz, 9999
0.01Hz
9999
89
0 to 400Hz, 9999
0.01Hz
9999
89
0 to 400Hz, 9999
0.01Hz
9999
89
0, 0.01 to 9998
0.001
0
144
0, 1
1
0
257
0 to 100%
0.1%
10%
140
0 to 400Hz
0.01Hz
6Hz
140
0 to 400Hz, 9999
0.01Hz
9999
140
101,
0 to 3600/360s
0.1/0.01s
5/10/15s
∗2
239
101,
0 to 3600/360s, 9999
0.1/0.01s
9999
239
0 to 30%, 9999
0.1%
9999
77
0 to 400Hz, 9999
0.01Hz
9999
90
0 to 200%, 9999
0.1%
9999
84
0 to 500A, 9999
0.01A
9999
108
0, 5, 7 to 12, 14, 20,
23 to 25, 52 to 57, 61,
1
0
145
62, 100
0 to 400Hz
0.01Hz
50Hz
150
Rated
0 to 500A
0.01A
inverter
150
current
0, 0.1 to 5s, 9999
0.1s
9999
153
0 to 60s
0.1s
1s
153
0, 1, 2, 3
1
0
98
0, 9
1
0
164
0 to 500A, 9999
0.01A
9999
106
0 to 200%, 9999
1%
9999
106
0 to 200%, 9999
1%
9999
106
0 to 5
1
0
161
0 to 400Hz
0.01Hz
50Hz
84
0 to 10, 101 to 110
1
0
161
0.1 to 360s
0.1s
1s
161
0
1
0
161
0 to 30%
0.1%
0%
121
0, 1, 3 to 6, 13 to 16, 23,
78, 81,
24, 40, 43, 44, 50, 53,
1
0
110,
54
112,
0 to 15
1
1
165
0, 1, 10, 11
1
1
167
Customer
Parameter
Remarks
Setting
30
31
32
33
34
35
36
37
40
41
42
43
44
45
46
47
48
51
52
55
56
57
58
59
60
61
62
63
65
66
67
68
69
70
71
72
73
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
1E
9E
0
1F
9F
0
20
A0
0
21
A1
0
22
A2
0
23
A3
0
24
A4
0
25
A5
0
28
A8
0
29
A9
0
2A
AA
0
2B
AB
0
2C
AC
0
2D
AD
0
2E
AE
0
×
×
×
×
2F
AF
0
30
B0
0
33
B3
0
34
B4
0
37
B7
0
38
B8
0
39
B9
0
3A
BA
0
3B
BB
0
×
×
3C
BC
0
3D
BD
0
3E
BE
0
3F
BF
0
41
C1
0
42
C2
0
43
C3
0
44
C4
0
45
C5
0
46
C6
0
47
C7
0
48
C8
0
49
C9
0
Parameter list
Parameter
Copy
Clear
All clear
4
×