Mitsubishi Electric FR-E700 Instruction Manual page 116

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

The setting range and increments of Pr. 82, Pr. 90 to Pr. 94 and Pr. 859 changes according to the setting value of Pr. 71 and
Pr. 96.
Applied Motor
Parameter
Function Name
Number
82
Motor excitation current
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
859
Torque current
∗1
When Pr. 71 = "0, 1, 40 or 50", or setting value of Pr. 96 read after performing offline auto tuning is not "3, 13, 23".
∗2
When Pr. 71 = "5, 6, 15, or 16"
∗3
When Pr. 71 = "3, 13, 23, 43 or 53" and setting value of Pr. 96 read after performing offline auto tuning is "3, 13, 23". Or when Pr. 71 = "4, 14, 24, 44 or 54".
POINT
This function is made valid only when a value other than "9999" is set in Pr. 80 and Pr. 81 and Advanced
magnetic flux vector control or General-purpose magnetic flux vector control is selected.
You can copy the offline auto tuning data (motor constants) to another inverter with the PU (FR-PU07).
Even when motors (other manufacturer's motor, SF-JRC, etc.) other than Mitsubishi standard motor, high
efficiency motor (SF-JR, SF-HR 0.2kW or more), and Mitsubishi constant-torque motor (SF-JRCA four-pole,
SF-HRCA 0.4kW to 15kW) are used or the wiring length is long, using the offline auto tuning function runs the
motor with the optimum operating characteristics.
Tuning is enabled even when a load is connected to the motor.
As the motor may run slightly, fix the motor securely with a mechanical brake or make sure that there will be no
problem in safety if the motor runs (caution is required especially in elevator). Note that tuning performance is
unaffected even if the motor runs slightly.
Reading/writing/copy of motor constants tuned by offline auto tuning are enabled.
The offline auto tuning status can be monitored with the operation panel and PU (FR-PU04/FR-PU07).
Do not connect a surge voltage suppression filter (FR-ASF-H/FR-BMF-H) between the inverter and motor.
(1)
Before performing offline auto tuning
Check the following before performing offline auto tuning.
Make sure Advanced magnetic flux vector control or General-purpose magnetic flux vector control (Pr. 80, Pr. 81) is
selected. (Tuning can be performed even under V/F control selected by turning ON X18.)
A motor should be connected. Note that the motor should be at a stop at a tuning start.
The motor capacity should be equal to or one rank lower than the inverter capacity.
The maximum frequency is 120Hz.
A high-slip motor, high-speed motor and special motor cannot be tuned.
As the motor may run slightly, fix the motor securely with a mechanical brake or make sure that there will be no problem
in safety if the motor runs (caution is required especially in elevator). Note that tuning performance is unaffected even if
the motor runs slightly.
Offline auto tuning will not be performed properly if it is performed with a surge voltage suppression filter (FR-ASF-H/FR-
BMF-H) connected between the inverter and motor. Remove it before starting tuning.
Internal Stored Value ∗1
Setting
Setting Range
Increments
0 to 500A, 9999
0.01A
0 to 50Ω, 9999
0.001Ω
0 to 50Ω, 9999
0.001Ω
0 to 1000mH, 9999
0.1mH
0 to 1000mH, 9999
0.1mH
0 to 100%, 9999
0.1%
0 to 500A, 9999
0.01A
Selection and protection of a motor
Direct Input Value ∗2
Setting
Setting Range
Increments
0 to 500A, 9999
0.01A
0 to 50Ω, 9999
0.001Ω
0 to 50Ω, 9999
0.001Ω
0 to 50Ω, 9999
0.001Ω
0 to 50Ω, 9999
0.001Ω
0 to 500Ω, 9999
0.01Ω
0 to 500A, 9999
0.01A
Auto Tuning Measured Value
∗3
Setting
Setting Range
Increments
0 to ****, 9999
1
0 to ****, 9999
1
0 to ****, 9999
1
0 to ****, 9999
1
0 to ****, 9999
1
0 to ****, 9999
1
0 to ****, 9999
1
113
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e740ec

Table of Contents