Mitsubishi Electric FR-E700 Instruction Manual page 197

Fr-e740-016 to 300 - ec; fr-e720s-008 to 110 - ec
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Selection of operation mode and operation location
(2)
Selects the command source of the PU operation mode (Pr. 551)
Any of the operation panel, PU connector, or USB connector can be specified as the command source in the PU operation
mode.
In the PU operation mode, set Pr. 551 to "2" when executing parameter write, start command or frequency command
during the RS-485 communication with PU communication.
NOTE
When performing the RS-485 communication with the PU connector when Pr. 551 = "9999", PU mode command
source does not automatically change to the PU connector. Change to the Network operation mode to change the
command source.
When "2" (NET mode PU connector) is set in Pr. 550 and "2" (PU mode PU connector) is set in Pr, 551, PU operation
mode has priority. When the communication option is not fitted, therefore, the operation mode cannot be switched to
the Network operation mode.
Changed setting value is valid when powering on or resetting the inverter.
The Modbus-RTU protocol cannot be used in the PU operation mode. Select Network operation mode (NET mode
command source).
All of the operation mode indicator (
operation panel.
PU...PU operation mode, NET...network operation mode, —....without command source
Pr. 550
Pr. 551
Operation
Setting
Setting
2
3
4
0
9999
(initial
value)
2
3
2
4
9999
(initial
value)
2
3
9999
(initial
4
value)
9999
(initial
value)
∗1
The Modbus-RTU protocol cannot be used in the PU operation mode. When using the Modbus-RTU protocol, set Pr. 550 to "2".
∗2
When the communication option is not fitted, the operation mode cannot be switched to the Network operation mode.
∗3
When Pr. 551 = "9999", the priorities of the PU command source is USB connector > parameter unit (FR-PU04/FR-PU07) > operation panel.
194
Command Source
USB
panel
connector
PU
PU
PU ∗3
PU ∗3
PU
PU
PU ∗3
PU ∗3
PU
PU
PU ∗3
PU ∗3
) of the operation panel turns OFF when command source is not
PU connector
Parameter
RS-485
unit
communication
PU ∗1
PU
PU ∗3
PU ∗1
PU
NET
NET
PU ∗3
NET
PU ∗1
PU
NET
NET
PU ∗3
NET
Communication
Remarks
option
NET ∗2
NET ∗2
NET ∗2
NET ∗2
Switching to NET
operation mode disabled
NET ∗2
Communication option
NET ∗2
fitted
Communication option
not fitted
Communication option
NET ∗2
fitted
Communication option
not fitted
Communication option
NET ∗2
fitted
Communication option
not fitted

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e740ec

Table of Contents