Download Print this page

Sharp AR-FX12 Service Manual page 52

Hide thumbs Also See for AR-FX12:

Advertisement

SW
Bit
Item
No.
No.
43
2
V.34 mode function
(when call in)
3-6 V.34Symbol Rate Mask
(when receiving)
7,8 Not used
44 1-4 V.34 mode transmission
speed
5-8 V.34 mode reception
speed
45
1
2800 Symbol Rate Mask
in V.34 communication
2
Not used
3
3000 Symbol Rate Low
Carrier setup in V.34
transmission
4
3000 Symbol Rate High
Carrier setup in V.34
transmission
5
3200 Symbol Rate Low
Carrier setup in V.34
mode
6
3200 Symbol Rate High
Carrier setup in V.34
transmission
7
3429 Symbol Rate Mask
in V.34 transmission
8
Communication error
sound setting when no
response from the
remote machine in FAX
reception
Switch selection and function
Used to set whether V.34 mode is enabled or not as a capacity of the own
machine when receiving (calling in).
1: V.34 mode function
disable
Used to set Symbol Rate in reception of V.34 mode.
When set to other than the below, it is set as the default (0101).
Bit No.
2400
2400
2800/2400
3000/2800/2400
3200/3000/2800/2400
3429/3200/3000/2800/2400
Used to set the communication speed (capacity) when transmitting in V.34
mode.
The set range is 2400bps - 33600bps in the increment of 2400bps by binary
input of N into "2400(bps) x N." When N is set to 0000, it is set to 2400bps.
When set to 1111, it is set to 33600bps. When, however, set to 2400bps, SW45-
1~6 must be disabled. When set to 33600bps, SW45-7 must be enabled "1".
Used to set the communication speed (capacity) when receiving in V.34 mode.
The set range is 2400bps - 33600bps in the increment of 2400bps by binary
input of N into "2400(bps) x N." When N is set to 0000, it is set to 2400bps.
When set to 1111, it is set to 33600bps. When set to 2400bps, however, SW43-
3~6 must be set to 2400: "0000."
When set to 33600bps, SW43-3~6 must be set to 3429: "0101."
Used to set Enable/Disable of 2800Hz as Symbol Rate of V.34.
When set to Disable, 2800Hz is not selected.
1: Disable
Used to set Enable/Disable of Low/High carrier when selecting 3000Hz as
Symbol Rate of V.34.When this is set to Disable, Low of 3000Hz is not selected.
It is valid only in transmission.
1: Disable
Used to set Enable/Disable of Low/High carrier when selecting 3000Hz as
Symbol Rate of V.34. When this is set to Disable, High of 3000Hz is not
selected. It is valid only in transmission. When both of Low/High are set to
Disable, Symbol Rate=3000Hz is not selected.
1: Disable
Used to set Enable/Disable of Low/High carrier when selecting 3000Hz as
Symbol Rate of V.34. When this is set to Disable, Low of 3200Hz is not
selected. It is valid only in transmission.
1: Disable
Used to set Enable/Disable of Low/High carrier when selecting 3000Hz as
Symbol Rate of V.34. When this is set to Disable, High of 3200Hz is not
selected. It is valid only in transmission. When both of Low/High are set to
Disable, Symbol Rate=3200Hz is not selected.
1: Disable
Used to set whether 3429Hz is used as Symbol Rate of V.34 or not.
When set to Disable, 3429Hz is not selected. Valid only in transmission.
1: Disable
Used to set whether the speaker sound is made or not according to the
communication error sound when the FAX signal cannot be received (when the
remote machine is a telephone in no response) from the remote machine in
FAX reception (call-in).
1: Error sound provided
AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-40
0: V.34 mode function
enable
3
4
5
6
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0: Enable
0: Enable
0: Enable
0: Enable
0: Enable
0: Enable
0: No error sound
USA
Initial value
Key
operator
0
Enable
0
3429
1
0
1
0
0
1
33600bps
1
1
0
1
33600bps
1
1
0
0
Enable
0
0
Enable
0
Enable
0
Enable
0
Enable
0
Enable
0
No error
sound

Advertisement

loading

This manual is also suitable for:

Ar-mm9