7)Attach the fax box unit.
<1>Secure screw A to the rack.
<2>Fit the positioning hole located on the side facing fax box unit to
screw A, slide the fax box unit toward the rack, and secure the rack
and the fax box unit using two screws B.
8)Connect the fax power supply connector.
<1>Ensure that the fax power switch is set to "OFF".
<2>Remove the screw from the connector cover for connection of the fax
power supply connector of the main unit and remove the connector
cover.
<3>Connect the fax power supply connector to the connector of the main
unit.
<4>Secure the connector by lightening the three screws on the
connector.
9)Connect the connector.
Connect the fax interface cable to the fax box unit and the control
PWB unit.
Connect the scanner cable that has been removed in step 2.
10)Turn on the power switches of the main unit.
Insert the power plug of the main unit to the outlet and turn on the
power switch of the main unit and the fax power switch of the box
unit.
11)Set the destination for the main unit.
• Be sure to set the destination for the main unit before setting the
destination for the fax.
<1>Switch the operation panel to the copy mode and use the key
operation [P], [*], [C], and [*] to enter the simulation mode.
<2>Use the 10-key pad to enter [26] in the main code entry screen and
press the [START] key.
<3>The sub-code list is displayed. Use the 10-key pad to enter [6] and
press the [START] key.
<4>Select the desired destination from the destination list by entering
the number and press the [START] key.
When you press the [START] key, this machine will be rebooted and
will start with the setting of the selected destination for the main unit.
Example: To set the UK as the destination, select it from the
destination list by entering [7] and press the [START] key.
12)Set the destination for the fax.
<1>Switch the operation panel to the copy mode and use the key
operation [P], [*], [C], and [*] to enter the simulation mode.
<2>Use the 10-key pad to enter [66] in the main code entry screen and
press the [START] key.
<3>Use the 10-key pad to enter [2] in the sub-code entry screen and
press the [START] key.