8 - 6
MC909X Integrator Guide
or
On the MC909X-K or MC909X-S, press and hold the left scan button.
Connect the mobile computer to AC power using the CAM or insert the mobile computer into a powered
9.
cradle.
The Update Loader application first looks for a file on a storage card. If it does not find it, it looks in the
10.
\temp directory.
When it finds the appropriate file, it loads the package onto the mobile computer. A progress bar displays
until the update completes.
The mobile computer re-boots.
11.
The calibration screen appears.
12.
NOTE When initiating an update via a boot sequence, the update loader looks for updates first on the root of an
installed SD card and then in the \temp folder on the mobile computer's persistent storage volume. A
response file, pkgs.lst, indicates which files to update. In most cases, Symbol provides this pkgs.lst file
with the update and you should only modify it when updating a splash screen partition. See
Splash Screen
for more information.