System Installation Guide; Alarm I/O Control - NetComm IP DSLAM NCT480 User Manual

Ip dslam
Hide thumbs Also See for IP DSLAM NCT480:
Table of Contents

Advertisement

Alarm I/O Control

The alarm I/O control allows you to define the alarm input and output. Please see "System Installation Guide"
for the definition.
Once the normal status of input signal is different from the current status, the NCT480 will launch an
"abnormal status" alarm of the specified output to terminal or administrator.
Item
Index 1~4
Alarm profile
Input value
Alarm status
Output value
Local temperature
Remote temperature
YML856 Rev3
www.netcomm.com.au
Figure 4-18 Alarm I/O Control Dialog
Description
This indicates the location of relay input ports (1 ~ 4).
This indicates the alarm profile of the specified relay input that configured by operator.
This indicates the current status of the specified relay input.
This indicates the alarm status.
This specifies the status of out alarm configuration.
0: always output 0
1: always output 1
0alarm: usually output 1, output 0 when alarm occur
1alarm: usually output 0, output 1 when alarm occur
This specifies the local alarm temperature value.
This specifies the remote alarm temperature value.
Table 4-14 Alarm I/O Control
NCT480 IP DSLAM User Guide
NCT480 IP DSLAM User Guide
5

Advertisement

Table of Contents
loading

Table of Contents