Switch. Terms/Usage In this guide, the term “Switch” (first letter upper case) refers to your NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch and “switch” (first letter lower case) refers to other Ethernet switches. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide...
INTRODUCTION This chapter describes the features of the NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 Web- SMART Switch and some background information about Fast Ethernet, Gigabit Ethernet, Switching, VLAN and Power over Ethernet technologies. Fast Ethernet Technology The growing importance of LANs and the increasing complexity of desktop computing applications are fueling the need for high performance networks.
PoE is already widely adopted in the market, saving up to 50% of overall installation costs by eliminating the need to install separate electrical wiring and power outlets. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Supports Port-setting for Speed/Disable, Flow control and Port based QoS (Quality of Service) • Easy configuration via Web Browser • Easy setting via Web Management Utility • Standard 19” Rack-mount size NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Leave at least 10cm of space at the front and rear of the hub for ventilation. • Install the Switch on a sturdy, level surface that can support its weight, or in an EIA standard-size equip- ment rack. For information on rack installation, see the next section, titled Rack Mounting.
Installing the Switch on a Desktop When installing the Switch on a desktop or shelf, the rubber feet included with the Switch should first be attached. Attach these cushioning feet on the bottom at each corner of the device. Allow enough ventilation space between the Switch and any other objects in the vicinity.
Page 10
Figure 3. Mount the Switch in the rack. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
1000Mbps Gigabit Ethernet runs in full duplex mode using four pair Category 5. These RJ-45 ports are Auto-MDI type port. The Switch can auto transform to MDI-II or MDI-X type, so you can just make an easy connection that without worrying if you are using a standard or crossover RJ-45 cable.
Page 12
AC Power The Switch uses the AC power supply 100-240V AC, 50-60 Hz. The power switch is located at the rear of the unit adjacent to the AC power connector and the system fan. The Switch’s power supply will adjust to the local power source automatically and may be turned on without having any or all LAN segment cables connected.
Note: Be sure that you recorded the settings of your device, else all settings will be erased when pressing the “Reset” button. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 5. Front panel view...
AC Power Connector: This is a three-pronged connector that supports the power cord. Plug in the female connector of the provided power cord into this connector, and the male into a power outlet. Supported input voltages range from 100-240V AC at 50-60Hz. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Blinking 100Mbps PoE Status Green NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 7. LED indicators of the Switch When the Power LED lights on, the Switch is receiving power. When the Power turns off or the power cord has improper connection.
Page 16
When the 100Mbps LED lights on, the respective port is connected to a 100Mbps Fast Ethernet network. When the respective port is connected to a 10Mbps Ethernet or 1000Mbps Gigabit Ethernet network. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
3. Click on the Install Web Utility button. 4. Follow the on-screen instructions to install the utility. 5. Upon completion, go to Program Files -> web_management_utility and execute the Web Management utility. (Figure 8.) NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Trap IP: Shows the IP where the Trap is to be sent. • Subnet Mask: Shows the Subnet Mask set of the device. • Gateway: Shows the Gateway set of the device. Figure 8. Web Management Utility NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
View Trap The Trap function can receive the events that happen on the Web Management Switch in the Monitor List. There is a light indicator behind the “View Trap” button. When the light is green, it means that there is no trap transmitted, and when it is red, it means that a new trap has been transmitted, reminding us to view the trap.
“Set” to process the data changed immediately. The default password of this 24-Port 10/100/1000Mbps Gigabit Ethernet Web Smart Switch configuration is “admin”. Figure 10. Trap information Figure 11. Configuration Setting NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
When the device has a new function, there will be a new firmware to update the device; use this function to upgrade the firmware. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 12. Password Change...
Choose 15 secs, 30 secs, 1 min, 2 min, and 5 min to select the time for monitoring. Help TAB In the “Help TAB”, there is About function, it will show out the version of the Web Management Utility. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Configuring the Switch The Switch has a Web GUI interface for smart switch configuration. The Switch can be configured through the Web Browser. A network administrator can manage, control, and monitor the Switch from the local LAN. This section indicates how to configure the Switch to enable its smart functions including: Port Setting, VLAN Set- ting, Trunking Setting, Port Mirroring, PoE Setting, Status, Statistics, System Setting, Trap Setting, Password Setting, Backup Setting, Reset Setting.
Mirror Settings, SNMP Settings, PoE Settings, Device Status, Statistic, System Settings, Trap Setting, Pass- word Settings, Backup Settings, and Reset Settings as shown in the Main Menu screen. Figure 17. Setup menu NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
To change the port setting, click on the ID parameter to enter the selected port to configure its Speed/Disable and Flow control. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 18. Port Configuration...
Page 26
In some ports that need to have a high priority to manage the data transfer, QoS should be change, Set the port’s QoS to high to determine the port will always transfer their data first. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
“Apply” button to execute the setting. Once you want to modify the VLAN Group, check on the ID parameter, the ID VLAN configuration window will pop out. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 20. VLAN Group Settings Figure 21.
“Apply” to activate the selected trunk group. Figure 23. Trunk Settings Be sure that the selected trunk setting port must connect to the device with a same VLAN group. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Port Mirroring is a method of monitoring network traffic that forwards a copy of each incoming and/or outgo- ing packet from one port of a network switch to another port where the packet can be studied. It enables the manager to keep close track of switch performance and alter it if necessary.
Figure 25. PoE Status Selected “POE Port Status” to configure the PoE Port setting. To configure the settings, press click on the ID parameter to enter to the selected port. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Page 31
Port 1 > Port 2 > … > Port 24. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 26. PoE Port Setting Select to enable or disable the PoE function.
Click on the “Status” button to display the device status on this screen. It will display the System Status, Port Status, VLAN Status, Trunk Status, Mirror Status and PoE Status. Press “Refresh” when you need to renew the posted information. Figure 28. System Status NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
The Statistics Menu screen will display the status of each port packet count. For detailed packet information, click on the ID parameter as Figure 30. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 29. Statistic...
Web Smart Utility and the time is up, you must re-login to Web Smart Utility before you set the Utility. Fill up the IP address, Subnet mask and Gateway for the device or enable DHCP get IP address from DHCP server. Figure 31. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Power on/Power off: Power over current: Power short circuit: Power threshold on/off: NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 32. Trap Setting Monitoring the system’s trap. a trap when booting up the system.
Figure 33.Set Password Backup Setting The backup tools help you to backup the current setting of the Switch. Once you need to backup the setting, press the “Backup” button to save the setting. To restore a current setting file to the device, you must specify the backup file and press the “Restore” button to process the setting of the recorded file.
DHCP server. Logout When you select this function, the Web configuration will log out and return to first Login page. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Figure 35. Reset Setting Figure 36. Logout...
Circuit shortage protect 100-240V AC, 50-60 Hz internal universal power supply 9Watts (max. no PD Device connected) 170Watts (max. with 11 x 15.4 w PoE Device connected) NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Page 39
Reduced Air Flow- Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
Page 40
Reliable Earthing- Reliable earthing of rack-mounted equipment should be maintained. Particular atten- tion should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips). NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
The wires form four pairs. Straight-Through Cables has same pinouts at both ends while Crossover Cables has a different pin arrangement at each end. NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1 Use EIA/TIA-568-100-Category 3, 4 or 5 cable.
To prevent loss of signal, make sure that the length of any twisted-pair connection does not exceed 100 metres. Figure 3 Wire Becomes Figure 4 Wire Becomes NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide YML842 Rev1...
APPENDIX C Registration and Warranty Information All NetComm Limited (“NetComm”) products have a standard 12 month warranty from date of purchase against defects in manufacturing and that the products will operate in accordance with the specifications outlined in the User Guide. However some products have an extended warranty option (please refer to your packaging).