System Specifications - NEC UNIVERGE NEAX 2000 IPS Reference Manual

Internet protocol server
Hide thumbs Also See for UNIVERGE NEAX 2000 IPS:
Table of Contents

Advertisement

Chapter 3 System Highlights

System Specifications

AC Power Requirements
Description
AC Input Voltage
AC Input Current
AC Power Consumption / Thermal Output (Maximum)
Description
1-PIM
2-PIM
3-PIM
4-PIM
5-PIM
6-PIM
7-PIM
8-PIM
Battery Requirements
Description
Max. Battery Capacity
DC Input Voltage for Battery
Built-in Battery Requirements
Physical Size of Built-in Battery
(one 12V battery)
Operating Environment
Description
Ambient Temperature
Relative Humidity
Electrical Characteristics (Central Office Trunk)
Description
Insulation Resistance
DC Resistance
Impedance
Leak Current
Page 3- 16
90 to 132Vac or 180 to 264Vac; 47 to 64Hz
3.5A(at 100V), 2.0A(at 200V)
AC Power Consumption (KVA)
100V
0.35
0.70
1.05
1.40
1.75
2.10
2.45
2.80
260AH per 4 PIM (65AH (12V) x 8)
-24V
3.4AH (12V) x 2 (approx. 30min. backup)
133(W) x 60(H) x 67(D) mm
0° to 40° Celsius
Max. 90% (non-condensing)
15 mega-ohms or more at 100Vdc
On-hook conditions: 30 mega-ohms
Off-hook conditions: 1,700 ohms
On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)
Looped conditions: 600 ohms
0 mA at on-hook conditions
UNIVERGE
Specifications
Thermal Output (BTU)
200V
100V
0.40
1,195
0.80
2,389
1.20
3,584
1.60
4,778
2.00
5,973
2.40
7,167
2.80
8,362
3.20
9,556
Specifications
Specifications
Specifications
8 kilo-ohms (at 24Hz)
2000 IPS Request For Proposal (RFP) Reference Guide
NEAX
200V
1,365
2,730
4,096
5,461
6,826
8,191
9,556
10,922
Issue 6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents