982 Errors - Lexmark CS310 Service Manual

Hide thumbs Also See for CS310:
Table of Contents

Advertisement

Error code
979.xx

982 errors

982 error messages
Error code
982.xx
990 errors
990 error messages
Error code
990.xx
Trays 2 and 3 (optional) service check
Actions
Step 1
Are two option trays being used?
Step 2
If two option trays are being used, then is the 550‑sheet tray on the
bottom?
Description
Flash parts failed while programming the
Standard Network or Network Card x port.
Check the following:
If installed, then check the network card for
correct installation.
If correctly installed, then replace the
network card.
If a network card is not installed, then
replace the controller board.
Description
Communications error detected by the
specified device.
Note: <device> can be one of the following:
Tray 2
Tray 3
Description
This error message indicates that an equipment
check condition has occurred in the specified
device.
Go to the service check for the device indicated.
Note: <device> can be one of the following:
Tray 2
Tray 3
Diagnostic information
Action
Go to
"Controller board removal" on
page
291.
Action
Call the next level of support.
Action
Go to
"Trays 2 and 3 (optional) service
check" on page
Yes
Go to step 2.
Go to step 4.
112
5027
112.
No
Go to step 4.
Go to step 3.

Hide quick links: