4.5.3 Notes on Advanced Uninterruptible Power Supply
(UPS)
Note the following cautions when using an advanced uninterruptible power supply (referred to as UPS
herein).
UPS shutdown time setting
Set a sufficient time interval of UPS power-off time (time from the shutdown command to the actual
power-off). If the interval is not adequate, the power will be cut off before system shutdown. It may
cause data collapse. For details, refer to the manuals of UPS and the UPS management software.
Power supply control by UPS
Change the BIOS settings to turn on the server automatically at power recovery or during scheduled
operation using the UPS management software (PowerChute Network Shutdown and PowerChute
Business Edition).
1
Start up BIOS Setup Utility.
"7.2.1 Starting and Exiting BIOS Setup Utility" (pg.151)
2
Click the [Power] menu and set [Power Failure Recovery] to [Always On].
3
Save the changes and exit BIOS Setup Utility.
PRIMERGY RX600 S4 User's Guide