Chapter 8 Operation and Maintenance
Uncorrected CPU Machine Check Architecture
(MCA) error
Memory configuration has changed - Run
SETUP
Unsupported memory configuration detected
Memory Redundancy Feature could not
configure the Mirror DIMMs
Memory Redundancy Feature could not
configure the spare DIMMs
Memory module failed! This module is no
longer available for the operating system.
CPU disabled! CPU is no longer available
for the operating system.
Resource Conflict
IRQ not configured
Expansion ROM not initialized
Allocation error static node
Baseboard Management Controller has
detected an error
iRMC reports sensor status: CRITICAL
temp
iRMC reports sensor status: WARNING
temp
188
table: List of POST error messages
Message
Description
It indicates a CPU error. Turn off the server and turn it back on. If
the message still appears, check the error log and replace the
relevant CPU. If the message still appears after the replacement,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
If the message appears when you replace the baseboard or
memory modules, start up BIOS Setup Utility, and select the
[Exit] menu – [Save Changes & Exit]. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".
It indicates a memory configuration error. Check whether the
same type of memory modules is installed within the same
memory paired bank, and the installation order is correct. If the
message appears although the configuration is proper, memory
modules may be defective. Replace the memory modules.
Memory mirroring function is not available because of the
incorrect memory configuration. Check whether the memory
modules are installed to meet the requirements for the memory
mirroring function. If the message appears although the
installation is proper, the memory modules may be defective.
Replace the memory modules.
Memory sparing function is not available because of the incorrect
memory configuration. Check whether the memory modules are
installed to meet the requirements for the memory sparing
function. If the message appears although the installation is
proper, the memory modules may be defective. Replace the
memory modules.
The message appears when memory modules are disconnected
because of a memory module error. Check the error log and
replace the relevant memory module. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
The message appears when CPUs are disconnected because of a
CPU error. Check the error log and replace the relevant CPU. If
the message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
It indicates a hardware resource error. Turn off the server and turn
it back on. If the message still appears, start up BIOS Setup
Utility, and select the [Exit] menu – [Save Changes & Exit]. If the
message still appears thereafter, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
iRMC has detected an error. Check the error log and replace the
relevant parts.
It indicates a temperature error/warning. Check the operating
environment and improve its condition if necessary. If the
message still appears, check the error log and replace the relevant
parts. If the message still appears thereafter, the baseboard must
be replaced. Contact an office listed in the "Contact Information"
of "Start Guide".