4.5.3 Notes on Advanced Uninterruptible Power Supply
(UPS)
Note the following cautions when using an advanced uninterruptible power supply (referred to as UPS
herein).
UPS shutdown time setting
Set a sufficient time interval of UPS power-off time (time from the shutdown command to the actual
power-off). If the interval is not adequate, the power will cut off before system shutdown. It may cause
data collapse. For details, refer to the manuals of UPS and the UPS management software.
Power supply control by UPS
Change the BIOS settings to turn on the server automatically at power recovery or during scheduled
operation using the UPS management software (PowerChute Network Shutdown and PowerChute
Business Edition).
1
Start the BIOS Setup Utility.
"7.2.1 Starting and Exiting the BIOS Setup Utility" (p.183)
2
Select [Power On/Off] in the [Advanced] menu, and press the [Enter] key.
"7.2.9 Power On/Off Submenu" (p.196)
The [Power On/Off] submenu screen appears.
3
Set [Power Failure Recovery] to [Always On].
4
Save the changes and exit the BIOS Setup Utility.

4.5.4 Using the Fiber Channel Controller (PG-FC202)

To use the Fiber Channel Controller (PG-FC202), the driver needs to be updated after installing the OS.
You can use the driver supplied with the Fiber Channel Controller or download it from the Fujitsu
PRIMERGY website (http://primergy.fujitsu.com).