Fujitsu PRIMERGY RX600 S4 User Manual page 129

Hide thumbs Also See for PRIMERGY RX600 S4:
Table of Contents

Advertisement

3
Start up BIOS Setup Utility.
"7.2.1 Starting and Exiting BIOS Setup Utility" (pg.151)
4
Select the [Server] menu – the [Memory Status] submenu, and check that the
item for the replaced memory module is set to [Enabled].
If it is set to [Failed], change it to [Enabled].
"7.2.15 Memory Status Submenu" (pg.167)
When the item corresponding to the replaced memory module is not set to [Enabled], the
server will start with the new memory module still marked as defective and always discon-
nected. By changing the setting to [Enabled], the new memory module is properly recognized
and it can be used at the next start of the server.
5
Release the error status of the defective memory.
Refer to "ServerView User's Guide" for the operational method.
PRIMERGY RX600 S4 User's Guide
129