Ni Motion Controllers With Velocity Amplifiers - National Instruments NI-Motion User Manual

Motion control
Table of Contents

Advertisement

Chapter 3
Tuning Servo Systems

NI Motion Controllers with Velocity Amplifiers

NI-Motion User Manual
Figure 3-6. Alternate Dual-Loop Feedback Algorithm
Velocity amplifiers close the velocity loop using a tachometer on the
amplifier itself, as shown in Figure 3-7. In this case, the controller must
ensure that the voltage output is proportional to the velocity. Use the
velocity feedforward term (Vff) to ensure that there is minimum following
error during the constant velocity profiles.
Figure 3-7. NI Motion Controllers with Velocity Amplifiers
in Addition to Kd
3-10
ni.com