National Instruments NI-Motion User Manual page 26

Motion control
Table of Contents

Advertisement

© National Instruments Corporation
Define control mechanism for I/O
Breakpoints*
2a
Define breakpoint position
Enable a breakpoint
Set data or image acquisition
device to trigger on breakpoint
Re-enable the breakpoint
after each occurrence
(absolute/relative/modulo
breakpoints only)
* Breakpoints cause a digital output to change state when a specified position is reached
by an encoder. Breakpoints are not supported by the NI SoftMotion Controller when it is
used with an Ormec or CANopen device.
** A high-speed capture records the position of an encoder when a digital line is used as
a trigger. High-speed captures are not supported by NI SoftMotion Controller for
CANopen. You can use two high-speed captures per axis when you are using the
NI SoftMotion Controller with an Ormec device.
Figure 2-2. Input/Output with Data and Image Acquisition
2-3
Chapter 2
Creating NI-Motion Applications
1
High-speed capture**
Define triggering input type
Enable high-speed capture
Read the captured position
Re-enable high-speed capture
after each occurrence
(non-buffered high-speed
capture only)
Chapter 12:
Synchronization
2b
NI-Motion User Manual

Advertisement

Table of Contents
loading