National Instruments NI-Motion User Manual page 49

Motion control
Table of Contents

Advertisement

Chapter 4
What You Need to Know about Moves
Update Rate
62.5 µs
2,048,000,000 counts/sec
125 µs
2,048,000,000 counts/sec
187.5 µs
910,222,222 counts/sec
250 µs
512,000,000 counts/sec
312.5 µs
327,680,000 counts/sec
375 µs
227,555,556 counts/sec
437.5 µs
167,183,673 counts/sec
500 µs
128,000,000 counts/sec
NI-Motion User Manual
You can calculate the maximum velocity with the following equation:
where
Vmax = 20 MHz for servos
8 MHz for steppers on a NI 7350 controller
4 MHz for steppers on a NI 7330, NI 7340, or NI 7390
motion controller
and is constrained by acceleration/deceleration according to the following
equation:
velocity ≤ (65,536 × deceleration) – acceleration
where velocity is in counts/sample and acceleration and deceleration are in
2
counts/sample
.
NI 73xx
Acceleration in Counts/s
Acceleration and deceleration values are converted to an internal
16.16 fixed-point format in units of counts/s
trajectory generator.
Table 4-2 shows the minimum and maximum acceleration update rates in
2
counts/sec
.
Table 4-2. Acceleration Update Rate in Counts/Sec
MAX
2
2
2
2
2
2
2
2
maximum velocity
=
2
MIN
2
3906 counts/sec
2
977 counts/sec
2
434 counts/sec
2
244 counts/sec
2
156 counts/sec
2
109 counts/sec
2
80 counts/sec
2
61 counts/sec
4-8
Vmax
2
before being used by the
2
Calculation Based
on Units
Accel
= MAX
max
Accel
= MIN
min
ni.com

Advertisement

Table of Contents
loading

Table of Contents