Master Offset - National Instruments NI-Motion User Manual

Motion control
Table of Contents

Advertisement

© National Instruments Corporation

Master Offset

If the material and welding point are not initially aligned, as shown in
Figure 10-16, the master offset must be applied to consider the position
difference.
Position = 50
When there is no master offset,
the master cycle begins at
position 0.
Figure 10-16. Misaligned Material and Welding Point
Without the master offset, the master device position is already inside the
first interval as soon as the first material passes the welding point.
Figure 10-16 shows that the master cycle intervals are offset by 50 counts.
The master interval is shifted from 0, 2,000, 4,000, and 6,000 to 50, 2,050,
4,050, and 6,050.
10-17
Chapter 10
Electronic Gearing and Camming
Position = 0
NI-Motion User Manual

Advertisement

Table of Contents
loading

Table of Contents