LabVIEW Code

1 Begin Program Storage
2 Insert Program Label
3 Select MOMO
4 Jump to Label on Condition
5 Run Program
© National Instruments Corporation
Figure 14-20 shows the main onboard program used to determine the
subroutine call.
3
1
2
5
6
4
6 Wait on Condition
7 Jump to Label on Condition
8 Insert Program Label
9 Run Program
Figure 14-20. Onboard Subroutine Call Using LabVIEW
14-35
Chapter 14
8
7
9
10
10 Wait on Condition
11 Jump to Label on Condition
12 End Program Storage
13 Motion Error Handler
Onboard Programs
11
12
13
NI-Motion User Manual