Handling Precautions For Electrical Parts And Wiring; Wiring - Kubota WSM B2050 Workshop Manual

Table of Contents

Advertisement

B2050, B2350, B2650, B3150, WSM
3. HANDLING PRECAUTIONS FOR ELECTRICAL
PARTS AND WIRING

[1] WIRING

To ensure safety and prevent damage to the machine and
surrounding equipment, obey the following precautions in handling
electrical parts and wiring.
IMPORTANT
• Check electrical wiring for damage and loosened
connection every year. To this end, educate the customer
to do his or her own check and at the same time
recommend the dealer to perform periodic check for a fee.
• Do not try to modify or remodel any electrical parts and
wiring.
• When removing the battery cables, disconnect the negative
cable first. When installing the battery cables, connect the
positive cable first.
(1) Negative Terminal
• Securely tighten wiring terminals.
(1) Correct
(Securely Tighten)
• Do not let wiring contact dangerous part.
(1) Dangerous Part (Sharp Edge)
(2) Wiring (Incorrect)
• Repair or change torn or aged wiring immediately.
(1) Aged
(2) Torn
G-3
GENERAL
(2) Positive Terminal
WSM000001GEG0062US0
(2) Incorrect
(Loosening Leads to Faulty Contact)
WSM000001GEG0063US0
(3) Wiring (Correct)
(4) Dangerous Part
WSM000001GEG0064US0
(3) Insulating Vinyl Tape
WSM000001GEG0065US0
KiSC issued 03, 2014 A