Slip Ring
1. Check the slip ring for score.
2. If scored, correct with an emery paper or on a lathe.
3. Measure the O.D. of slip ring with vernier calipers.
4. If the measurement is less than the allowable limit, replace it.
Factory specification
Slip ring O.D.
Allowable limit
Brush Wear
1. Measure the brush length with vernier calipers.
2. If the measurement is less than allowable limit, replace it.
3. Make sure that the brush moves smoothly.
4. If the brush is damaged, replace it.
Factory specification
Brush length
Allowable limit
Rectifier
1. Check the continuity across each diode of rectifier with an
analog ohmmeter. Conduct the test in the (R × 1) setting.
2. The rectifier is normal if the diode in the rectifier conducts in one
direction and does not conduct in the reverse direction.
IMPORTANT
• Do not use a 500 V megohmmeter for measuring because it
will destroy the rectifier.
NOTE
• Do not use an auto digital multimeter. Because it's very
hard to check the continuity of rectifier by using it.
IC Regulator
1. Check the continuity across the B terminal and the F terminal of
IC regulator with an analog ohmmeter. Conduct the test in the
(R × 1) setting.
2. The IC regulator is normal if the IC regulator conducts in one
direction and does not conduct in the reverse direction.
IMPORTANT
• Do not use a 500 V megohmmeter for measuring because it
will destroy the IC regulator.
NOTE
• Do not use an auto digital multimeter. Because it's very
hard to check the continuity of IC regulator by using it.
9-S45
ELECTRICAL SYSTEM
14.4 mm
0.567 in.
12.8 mm
0.504 in.
9Y1210982ELS0093US0
10.5 mm
0.413 in.
8.4 mm
0.331 in.
9Y1210982ELS0094US0
9Y1210982ELS0095US0
9Y1210982ELS0096US0